• Telling Seq not to use up the C drive

    Sandy Milne
    Sandy Milne
    To tell Seq to store its log files elsewhere Uninstall Seq from its current location on C: (Details for uninstall from Seq website ) Use the Seq “backup and restore” functionality to move the data to the intended new location (About backup-restore…
    • over 2 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • Configuring retention policy for Seq logging

    Sandy Milne
    Sandy Milne
    If you want to move Seq's logs off your server's C drive, please refer to the software's help page on that topic ! Why does Seq need a retention policy Seq's extent files will consume "infinite" amounts of disk space unless a retention policy is…
    • over 2 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • Configure email notifications of Dead Letters

    Sandy Milne
    Sandy Milne
    APM has used a Seq plug-in to provide email notification when a BOD message goes into the Dead Letter Queue . The specific version is seq.app.emailplus.2.0.87. Email+ Emailplus Settings
    • over 3 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • CMMS adapters need to use these values

    Sandy Milne
    Sandy Milne
    There are a specific pair of Sync BOD fields that must match specific values in the APM database. These are RegistrationSite InfoSource Registration Site The RegistrationSite's IDInInfoSource must match the APM user key of an APM site. In…
    • over 3 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • Create a debug Message Archive

    Sandy Milne
    Sandy Milne
    When first creating an adapter, and iterating through rounds of debugging, you may want to keep a record of ALL the messages submitted. Note for production Regardless of environment, there is a maximum combined size for all of a topic's subscriptions…
    • over 2 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • SEQ Memory Usage

    Sandy Milne
    Sandy Milne
    Troubleshooting: Memory usage always at 90% or above? It's probably this SEQ setting. Important Note: more details are available in the AWEIS Setup Guide. See the section named 'Setting up Logging...' By default, SEQ will use as much memory as possible…
    • over 3 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • On premise RabbitMQ

    Sandy Milne
    Sandy Milne
    The RabbitMQ administration page is at port 15672 of the interop server. For example, http://localhost:15672
    • over 4 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • RabbitMQ: Exchange names

    Sandy Milne
    Sandy Milne
    Launch RabbitMQ's administration page, which is at port 15672 of the interop server. For example, http://localhost:15672. Go to the Exchanges tab To confirm the exact name and spelling of the exchange (topic) to embed in the URL, look at the yellow…
    • over 4 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki
  • Turn on Service Bus Debug logging - On Premise

    Sandy Milne
    Sandy Milne
    Here is how to increase the level of detail in the Interop Service logs, for when you need to do detailed troubleshooting. Stop the service temporarily Stop the interop service - it's named BentleyInteroperabilityService How to: Launch the…
    • over 3 years ago
    • AssetWise Enterprise Interoperability
    • AssetWise Enterprise Interoperability Wiki