Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D PLAXIS 3D
Date created
25 August 2023
Date modified
25 August 2023
Original author
Vasileios Basas - Bentley Technical Support Group
When viewing nodal interface…
My WaterCAD version has a specific limit of 10,000 pipes for computing a scenario. I currently have 10,966 pipes. Due to the nature of the GIS model that was imported in the model builder, many of these same diameter pipes were made up of multiple polylines…
In WaterCAD, I imported a set of two shapefiles from GIS using ModelBuilder. The first shapefile was the general layout of a watermain with the pipe lengths and pipe diameters. For this model, I opted for modelbuilder to automatically create nodes. After…
I have a few conduits that are free outfalls but when I was changing their elevations the end nodes changed to the default headwall display. Nothing has changed other than the elevations.
Is there a list of conditions under which node numbers in RAM Frame will renumber automatically? I assumed, incorrectly, that node numbers would likely stay intact if grids or columns moved but were not deleted, but that appears not to be the case. It…
Applies To
Product(s):
STAAD.Pro
Version(s):
All
Environment:
N/A
Area:
Modeling Solutions
Subarea:
Geometry
Original Author:
Phil Riegel, Technical Support Group
…
Hello sirs!
Im recently started to learn Staad Pro and i want to know if im going to ignore duplicated nodes while in the Physical Modeller or is there a button or somewhere i can just delete those nodes? When i run the validate check i get the warnings…
I created a custom drainage node. I want it to skew and shift it orientation with respect to the inlet. I changed the rotation and location of the bottom cell with respect to the alignment line and the point, however the cell translation has not updated…
The RM Bridge Analyzer: Properties: Cross Sections: FE Mesh Move and Rotate the Nodes is a button with an option to modify current cross-section properties to achieve specific purposes. It is important to note that this function is principally related…
Is there a Node limit when using ORD Drainage & Utilities... by itself. What I mean is in order to model a larger site/corridor, with over 100 drainage nodes, can this be done just using ORD Drainage and Utilities? Or do we have to use one of the other…
I have a couple storm sewer utility runs drawn.
Where one of my nodes have 3 different conduits connect too, in the properties how ever it only shows one
connecting link. I'm attempting to resolve this so i can annotate all of the connecting conduit…
Hi,
I would like to use custom node (Tool - "Place Nodes") in my deign, but I have problem with adding custom cell. I've created custom cell, put into Feature Symbologies, add all configurations to display it. I've also defined feature definition…
At RM Bridge inside OpenBridge Designe r, at Modeler , in the Cross-section creation users have the opportunity to generate an FE-mesh. Though, the connections between elements must obey specific very basic FEM rules:
Corner nodes must only connect…
There are a few ways to isolate overlapping nodes with Voyager.
One example is provided below, where the first Network program outputs the node table defining rounded values of X and Y with a certain tolerance (imposed in the script).
The second…
Hello,
I'd like to know if there is a way to select an entire group of nodes with the same demand pattern. I have a model with several patterns, so I want to select all the nodes of each pattern that I have. Is there any way... Thanks in advance.
…
How can I set up my curb grate inlet to read my proposed terrain that gives me a correct longitudinal slope and cross slope? The current slopes show up as 100% which are obviously not desired or reflected on the terrain. I suspect it is from the curb…
Question regarding symbology for drainage nodes. Is it possible for a drainage node to have different symbology for the top and bottom?
The reason for the question is that a project may require using an existing bottom structure and just replacing the…
I was wondering if theres a simpler way to replace a drainage node with a different node type. IE i have an existing drainage layout but want to swap an inlet to another type without deleting and replacing the node in the same location.
I am currently using OpenRoads Designer to lay out some drainage networks. We have a few flumes in our system. The flumes need to extend behind sidewalk, however the default length of the node placed cannot be edited.
Would we have to create new nodes…
I am trying to go back through an imported model and insert vertical supports. In order to do this, you have to have a node to insert the support.
When I consulted the autopipe tutorial guide, it suggested inserting a new run across the existing pipe…
By assigning different Part numbers to isolated cross-sectional elements at the Cross-Sections in RM Bridge Modeler users will create also isolated beam elements and nodes in the RM Bridge Analyzer section. This is very useful to have only one reference…
Hello,
There are times I want to hide, not delete, certain nodes, elements, members when building a model - I may determine I want to use these again therefore I do not want to delete. I know I can "comment" them out using an asterisk in the STAAD editor…
Product(s):
OpenSite, OpenRoads, Open Rail
Version(s):
10.07.00.56+
Area:
Drainage and Utilities Feature Definitions - Overview
The PDF document below gives an overview of Feature Definitions used by the Drainage and Utilities…