I am trying to simulate the effect of the installation of PVDs on soft soil (soil model used: MCC). The installation of PVD (in this case, a line drain) causes disturbance to the soil and creates three zones around the soil. A smear zone, a transition…
I would like to display the hydraulic conductivity / permeability from the Laboratory Permeability grid, but want to utilize a scientific notation.
How can I do this?
Thanks!
Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D PLAXIS 3D
Original Author
Y. K. Wong
Date created
23 September 2013
Date modified
24 October 2016
This paper compares the performance of drainage line elements…
Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D 2017 PLAXIS 3D
Date created
04 July 2017
Date modified
04 July 2017
When modelling semi-permeable or impermeable structures like retaining walls or tunnel linings…
Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D 2017 PLAXIS 3D 2017
Date created
05 July 2017
Date modified
17 February 2022
For the case of semi-permeable interfaces , the output program shows the resulting specific…
Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D 2017 PLAXIS 3D 2017
Date created
03 July 2017
Date modified
03 July 2017
PLAXIS 2D 2017 and PLAXIS 3D 2017 have has several new features. One of them is permeability…
Application
PLAXIS 2D PLAXIS 3D
Version
PLAXIS 2D PLAXIS 3D
Date created
18 April 2017
Date modified
18 April 2017
This movie demonstrates how to apply the cross and parallel permeability options for interfaces…
Application
PLAXIS 2D PLAXIS 3D
Issue status
Solved
First Affected Version
PLAXIS 2D 2017 PLAXIS 3D 2017
Found in Version
PLAXIS 2D 2017 PLAXIS 3D 2017
Fixed and Released in Version
PLAXIS 2D CONNECT Edition V20 Update…
Application
PLAXIS 2D
Issue status
✔ Solved
First Affected Version
PLAXIS 2D 2015.00
Found in Version
PLAXIS 2D 2015.00
Fixed and Released in Version
PLAXIS 2D 2016.00
Issue #
24357
Date created …
Application
PLAXIS 2D
Issue status
Solved
First Affected Version
PLAXIS 2D 2011.00
Found in Version
PLAXIS 2D 2011.00
Fixed and Released in Version
PLAXIS 2D AE PLAXIS 2D Classic
Issue #
20424
Date created…
Application
PLAXIS 2D
Issue status
✔ Solved
First Affected Version
PLAXIS 2D AE.00
Found in Version
PLAXIS 2D AE.00
Fixed and Released in Version
PLAXIS 2D AE.02
Issue #
20429
Date created
07 May…
Application
PLAXIS 3D
Issue status
✔ Solved
First Affected Version
PLAXIS 3D 2011.00
Found in Version
PLAXIS 3D 2011.00
Fixed and Released in Version
Solved in a recent version
Issue #
16109
Date…
Q: What causes message "*** ERROR: TANK1 adds negative weight either permeability or definition wrong"? REV 6.02