• Modeling a separate spillway (weir) and Riser in a pond

    Jesse Dringoli
    Jesse Dringoli
    Product(s): PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem What is the best way to model a pond that has a spillway (weir) that operates separately from (in parallel with) another outlet structure such as…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Re: stage discharge for a pond

    Jesse Dringoli
    Jesse Dringoli
    Yes, the stage-discharge table can be entered as a user-defined rating curve in a composite outlet structure connected to a pond. The stage-storage would be entered in the pond itself, by selecting elevation-volume as the pond volume type.
    • over 11 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum