• Deconfinement method gives unexpected results in case of pore water pressure change in PLAXIS 2D

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2018.00 Found in Version PLAXIS 2D CONNECT Edition V20 Update 2 Fixed and Released in Version PLAXIS 2D CONNECT Edition V20 Update 4 Issue…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • How does Plaxis deal with water pressures during dynamic calculations?

    Stefanos Papavasileiou
    Stefanos Papavasileiou
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D CONNECT Edition PLAXIS 3D CONNECT Edition Date created 15 September 2014 Date modified 16 December 2022 In relation to water pressures in a dynamic calculation we…
    • 10 months ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Workflow of PLAXIS 2D - 04: Water conditions

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Version PLAXIS 2D AE Date created 20 February 2014 Date modified 20 February 2014 In this movie, we will focus on the fourth mode of PLAXIS 2D: the Water mode. In this mode, you can define…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • PLAXIS 2D PlaxFlow

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Version PLAXIS 2D AE.00 Date created 09 May 2011 Date modified 09 May 2011 To demonstrate the possibilities of Plaxis 2D Plaxflow, we show how to create a time-dependent water head. In Output…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Interpolated pore pressures in interfaces might be incorrect

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2015.00 Found in Version PLAXIS 2D 2015.00 Fixed and Released in Version PLAXIS 2D 2017.01 Issue # SW-12094 Date created…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Interpolate pore pressure option may give bug report during 3D calculation

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2013.00 Found in Version PLAXIS 3D 2013.00 Fixed and Released in Version PLAXIS 3D AE.02 Issue # 21597 Date created 10…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Pore pressures in interfaces may be incorrect with Interpolate pore pressures

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2015.00 Found in Version PLAXIS 2D 2015.00 Fixed and Released in Version PLAXIS 2D 2015.01 Issue # 23112 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Safety analysis after fully coupled flow-deformation analysis uses incorrect pore pressures

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 2D AE.00 PLAXIS 3D 2013.00 Found in Version PLAXIS 2D AE.00 PLAXIS 3D 2013.00 Fixed and Released in Version PLAXIS 3D 2017.00…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Interpolate pore pressures on volumes with vertical sides may give incorrect pore pressure distribution for PLAXIS 3D

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2013.00 Found in Version PLAXIS 3D 2013.00 Fixed and Released in Version PLAXIS 3D AE.01 Issue # 22162 Date created 10…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Incorrect interface active pore pressures

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2013.00 Found in Version PLAXIS 3D 2013.00 Fixed and Released in Version PLAXIS 3D 2013.01 Issue # 20017 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Degree of consolidation phase does not automatically take pore pressures from previous phase

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2012.00 Found in Version PLAXIS 3D 2012.00 Fixed and Released in Version PLAXIS 3D AE.00 Issue # 19642 Date created 31…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Consistent use of PLAXIS Output

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 2D 2012.00 PLAXIS 3D 2012.00 Found in Version PLAXIS 2D 2012.00 PLAXIS 3D 2012.00 Fixed and Released in Version PLAXIS 2D AE PLAXIS…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Incorrect interface pore pressures after groundwater flow

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2012.00 Found in Version PLAXIS 3D 2012.00 Fixed and Released in Version Solved in a recent version Issue # 19541 Date…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Active pore water stresses and total stresses incorrect in interfaces for Undrained C material

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010.01 Found in Version PLAXIS 2D 2010.01 Fixed and Released in Version PLAXIS 2D AE.00 Issue # 19721 Date created 28…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Use pressures from previous phase-option gives wrong pore pressures after changing the previous phase

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2012.00 Found in Version PLAXIS 3D 2012.00 Fixed and Released in Version PLAXIS 3D 2013.01 Issue # 19560 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Degree of saturation is shown as 0% for undrained layers when p_active > 0

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2012.00 Found in Version PLAXIS 2D 2012.00 Fixed and Released in Version Solved in a recent version Issue # 19155 Date…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 3D2011.00 Groundwater flow does not take the volume-dry-setting into account

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status Open First Affected Version PLAXIS 3D 2011.00 Found in Version PLAXIS 3D 2011.00 Fixed and Released in Version Issue # 14968 Date created 30 June 2011 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Saturation is 0% for phreatic level calculations in PLAXIS 3D 2011.00

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status Open First Affected Version PLAXIS 3D 2011.00 Found in Version PLAXIS 3D 2011.00 Fixed and Released in Version Issue # 14892 Date created 30 June 2011 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D2011.00: Default pore pressure calculation is taken from the previous phase instead from the parent phase

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2011.00 Found in Version PLAXIS 2D 2011.00 Fixed and Released in Version Issue # 16034 Date created 02 January 2012 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D2011: (External) water loads wrongly applied during safety and dynamic calculations

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2011.00 Found in Version PLAXIS 2D 2011.00 Fixed and Released in Version Issue # 16342 Date created 02 January 2012 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • New on-demand video for November's Geotechnical Analysis SIG: PLAXIS CONNECT Edition: Excavation Dewatering and Common Pitfalls!

    Micha van der Sloot
    Micha van der Sloot
    We posted the recording of our November 2019 SIG on Excavation Dewatering and Common Pitfalls in PLAXIS 2D and PLAXIS 3D on the Bentley LEARN server in the Geotechnical Learning Path: https://learn.bentley.com/app/Public/ViewLearningPathDetails?lpId=113626…
    • over 3 years ago
    • OpenGround | gINT | Keynetix
    • OpenGround | gINT | Keynetix Announcement Forum