Good Morning,
I have a really complicated situation,
My model has two reservoir's and each reservoir have two pumps,
Reservoir 1 designed to produces 4000 GPM (Combined two pumps)
Reservoir 2 designed to produces 1850 GPM (Combined two pumps…
Product(s):
WaterGEMS, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Modeling
Problem
When modeling a pump in WaterGEMS, is there a way to have the pump turn off, but still allow flow through the pump. Problem…
Hi John:
There are a couple of different ways to model this in your system, depending on how much information you have and the behaviour of your pumps. I'm going to assume you're doing extended period simuation modeling, since that's the only…
So you have a logical control on the PRVs that says something like "set PRV pressure setting to 105psi when the pump is off"?
I think the problem is that the PRV control isn't checked until after the pump goes off - giving you that 0.1hr delay…