Hello
i would like to study a surge effect in sewage transmission line consist from lefting station of 1 submarsible pump .. water will be pumped by the submarsble pump for 1.5 km to a manhole . how can i model that submarsable pump in water hammer…
Product(s):
HAMMER
Version(s):
10.XX.XX.XX, 08.11.02.31 and greater
Area:
Calculation
Problem
How can you change the Accuracy and Maximum Trials for the transient calculation engine?
Transient results appear to be unstable…
Applies To
Product(s):
WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm
Version(s):
08.11.XX.XX
Area:
Layout and Data Input
Problem
How do I develop a pump curve if the only known information is…
Applies To
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Data Input
Original Author:
Mark Pachlhofer, Bentley Technical…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
V8i, CONNECT Edition
Area:
Layout and Data Input
Problem
How can I use patterns to change the pump speed over time (or turn it on/off based on time), or reservoir hydraulic…
Hi
I have encountered some times this problem. I have a flow in the existence pipe of a reservoir or pump in model. I know the demand consumes in the network and use that in junctions. I have measured the outflow with a portable flowmeter or a fixed…
Applies To
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i
Original Author:
Mark Pachlhofer, Bentley Technical Support Group
Problem
Fire flow nodes are failing the zone or system pressure…
Applies To
Product(s):
HAMMER
Version(s):
10.00.xx.xx, 08.11.xx.xx
Area:
Modeling
Original Author:
Scott Kampa, Bentley Technical Support Group
Problem
After computing the transient analysis, a user notification…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
08.11.XX.XX and 10.00.XX.XX
Area:
Layout and Data Input
Problem
Why is the “lag pump count” field not available when selecting Target Flow as the “VSPB Type”?
How can the…
Product(s):
HAMMER
Version(s):
08.11.XX.XX and 10.00.XX.XX
Area:
Layout and Data Input
Problem
Why do I need to enter a "nominal head" and "nominal flow" when modeling a pump startup event?
Solution
When modeling a pump…
Applies To
Product(s):
HAMMER
Version(s):
CONNECT Edition, V8i
Area:
Analysis/Computation
Original Author:
Jesse Dringoli, Bentley Technical Support Group
Problem
How do I solve the following…
Applies To
Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Original Author:
Scott Kampa, Bentley Technical Support Group
Problem
After computing a…
We are trying to model a pump startup scenario in HAMMER (v 8.11.03.17) with the pump starting 10 seconds into the simulation and the discharge valve starting to open up 15 seconds into the simulation. We followed the Tech Note for startup scenario but…
You can experiment with the effects of inertia in the model by changing each pump's inertia value (go to Components > Pump Definitions > Transient). However remember that the inertia (pump and motor combined) is dependent on the actual pump and motor…
Hello,
I am using Hammer V8i.
I have a simple layout for a pump station transient model. A pump draws from a wet well, and discharges over a syphon into an effluent conduit. The discharge syphon creates a negative pressure at steady state. My transient…
I have a query about how Hammer deals with the Rating Curve option. In the Hammer Help file, the following information is all that is provided:
Rating Curve - releases water from the system to atmosphere based on a customizable rating curve relating…
Hi Shannon,
Hopefully you have also sent these questions to the Tech Support Group, as they can typically provide a faster response than you might get over the forums...however, if you are still needing help:
- The Pump element in HAMMER…
Using a flywheel to increase pump intertia is certainly a solution that has been used by others to try and minimize the effects of transients.
As for whether or not it is a good solution in this case, I think that is something you would need to…