• Notificação do usuário: "Pump cannot deliver flow or head"

    Luca Santos Billis
    Luca Santos Billis
    Aplica-se a Produto(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Versão(ões): CONNECT Edition, V8i Área: Cálculos Autor Original: Terry Foster, Grupo de Suporte Técnico da Bentley Problema…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • How do i set up a known Pump and Hydropneumatic?

    Jose Ramon Guzman Guzman
    Jose Ramon Guzman Guzman
    on the model that im doing, I will have to add and use a pump and a hydfropneumatic that are already on site. But I get confused when I neeed to add the definition of the pump curve and the hydropneumatic data. For the pump i have a Pedrollo Cp670 with…
    • Answered
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How to develop a pump curve for a well pump when the only information I have is the well capacity(MGD)? [WaterGEMS]

    Varenya Mehta
    Varenya Mehta
    I have a model for a city(In WaterGEMS) with multiple Groundwater/Surface Water/Repump stations. Apparently, one of the Groundwater well pump has incorrect pump curve (head vs flow). I need to develop a new pump curve with the only info on hand being…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Find if pump operates off of the pump curve during an automated fire flow scenario

    Larry Abla
    Larry Abla
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Is there a way to see if a pump is operating off the pump curve during an automated fire flow scenario? Solution …
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User Notification: "Pump cannot deliver flow or head"

    Luca Santos Billis
    Luca Santos Billis
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Original Author: Terry Foster, Bentley Technical Support Group Problem…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User notification "Pump exceeds the maximum operating point specified for the pump curve"

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem My pumps are operating at a much higher…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Estimating a pump curve for a model

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem How do I develop a pump curve if the only known information is…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Re: Pump flow

    Mal Sharkey
    Mal Sharkey
    If the pump is 30 years old and you entered the original pump curve in the model, then that could explain also some differences (since the pump is not likely to be giving the same performance now as it did back when it was first installed). You…
    • over 15 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: Pump Curve shape does not match data points.

    Mal Sharkey
    Mal Sharkey
    Hi Karl, Go to Analysis > Calculation Options and edit your existing Steady State / EPS calc option set(s). In the calc options you will find a section called Hydraulics, and in there is an option called "Use Linear Interpolation for Multipoint…
    • over 14 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum