• Notificação do usuário: "Pump cannot deliver flow or head"

    Luca Santos Billis
    Luca Santos Billis
    Aplica-se a Produto(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Versão(ões): CONNECT Edition, V8i Área: Cálculos Autor Original: Terry Foster, Grupo de Suporte Técnico da Bentley Problema…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • Estação de bombeamento e combinação de curvas de bombas

    Luca Santos Billis
    Luca Santos Billis
    Aplica-se a Produto(s): WaterGEMS , WaterCAD, SewerCAD Versão(ões): V8 i SELECTseries 2 and higher, CONNECT Edition Área: Modelagem Autor Original: Mark Pachlhofer, Grupo de Suporte Técnico da Bentley…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • Solução de problemas de pressões negativas em bombas, junções e outros elementos de nós

    Luca Santos Billis
    Luca Santos Billis
    Aplica-se a Produto(s): WaterGEMS, SewerCAD, HAMMER, WaterCAD Versão(ões): V8i, CONNECT Edition Área: Modelagem Autor Original: Dan Iannicelli , Mark Pachlhofer e Jesse Dringoli, Grupo de Suporte Técnico…
    • 5 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • Simulating an existing water distribution system in waterGems and optimising it on the basis of Pattern variation.

    PUSHPENDERSINGH DEVAL
    PUSHPENDERSINGH DEVAL
    Hello everyone, I am trying to simulate an existing water distribution system into waterGEMS and later I wish to alter it's patterns of pumping, demand, etc.. in order to optimise it in terms of energy consumption. THE PHYSICAL NETWORK HAS BEEN CREATED…
    • Answered
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • PSV Settings and Reverse Flow through Pump

    Mark Medina
    Mark Medina
    First I have a PSV and I was wondering if someone could explain the difference in setting it to the max elevation of the tank and the minimum elevation of the tank and if the sets below were correct way of doing it. When I set it to the max elevation…
    • Answered
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Modeling pump dicharge regardless of waterdemand

    Gashin Shahsavari
    Gashin Shahsavari
    I'm modelling an underpressure network with a pumping station including various pumps. The model is buildup and base demands are given to the network. The demands are based on the pupulation off 3 years ago. Actually in the reality the population has…
    • Answered
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • negative pressure - groundwell [ submersible pump - what is the problem ?? please help

    Twana Ismail
    Twana Ismail
    i dont know what is the problem of this system pump definition is good elevation of nodes is correct i increased the trials to 200 i added a imaginary tank but presuure is -16 000 kPa right at top of the well what is the problem ???
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Modeling a Connection to an Existing System

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Authors : Scott Kampa, Jesse Dringoli, Tom Walski Background If you are modeling only a portion of a larger…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Pump selection for a closed system

    Sushma Choure
    Sushma Choure
    Product(s): WaterCAD, WaterGEMS Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When designing a closed system with only demands downstream (no storage), how can the program help me select a pump? The system head…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Estimating a pump curve for a model

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem How do I develop a pump curve if the only known information is…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to develop a pump curve for a well pump when the only information I have is the well capacity(MGD)? [WaterGEMS]

    Varenya Mehta
    Varenya Mehta
    I have a model for a city(In WaterGEMS) with multiple Groundwater/Surface Water/Repump stations. Apparently, one of the Groundwater well pump has incorrect pump curve (head vs flow). I need to develop a new pump curve with the only info on hand being…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Modeling multiple pipes downstream of a pump

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Original Author: Mark Pachlhofer, Bentley Technical…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User Notification: "Pump cannot deliver flow or head"

    Luca Santos Billis
    Luca Santos Billis
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Original Author: Terry Foster, Bentley Technical Support Group Problem…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Simulate bypass flow through a pump that is turned off

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem When modeling a pump in WaterGEMS, is there a way to have the pump turn off, but still allow flow through the pump. Problem…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using patterns to control pumps or reservoir HGL over time

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem How can I use patterns to change the pump speed over time (or turn it on/off based on time), or reservoir hydraulic…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How do you associate a pump to a pump station?

    Sushma Choure
    Sushma Choure
    Product(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How do you associate a pump to a pump station? What is the difference between a pump…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • The flow out of my pump is zero, but the pump is set to ON and is active.

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem The flow out of my pump…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Fire flow nodes are failing because of low pressures on the suction side of a pump

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Fire flow nodes are failing the zone or system pressure…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Pump Station and Pump Combination Curves

    Luca Santos Billis
    Luca Santos Billis
    Applies To Product(s): WaterGEMS , WaterCAD, SewerCAD Version(s): V8 i SELECTseries 2 and higher, CONNECT Edition Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group …
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User Notification: Multiple point pump curve contains non-increasing flow points.

    Craig Calvin
    Craig Calvin
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX and 10.00.00.XX Area: Layout and Data Input Problem When computing or validating the model the following user notifications appear. Multiple…
    • over 6 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • After computing the model, the pump efficiency results are listed as N/A

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem After computing the model, the pump efficiency results listed as N/A in the pump properties or the pump…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How do I find the Total Dynamic Head (TDH)?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, SewerCAD, WaterCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Problem How can I find the Total Dynamic Head (TDH) of one or more pumps? Solution The Total Dynamic…
    • 4 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Why is the “lag pump count” field not available when selecting Fixed Flow as the “VSPB Type”?

    Craig Calvin
    Craig Calvin
    Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): 08.11.XX.XX and 10.00.XX.XX Area: Layout and Data Input Problem Why is the “lag pump count” field not available when selecting Target Flow as the “VSPB Type”? How can the…
    • over 6 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Troubleshooting negative pressures at pumps, junctions, & other node elements

    Ankit Kulkarni
    Ankit Kulkarni
    Applies To Product(s): WaterGEMS, SewerCAD, HAMMER, WaterCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Dan Iannicelli , Mark Pachlhofer, and Jesse Dringoli, Bentley Technical Support…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Why can't I reach my desired flow in my pump model

    Zeinab Amiri
    Zeinab Amiri
    Hello I have designed a well pump in watergems. I got the error messages of negative pressure and exceeding the maximum operating point specified for the pump curve. I was able to solve these problems by changing my pumps, correcting my pump curves…
    • Answered
    • over 8 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
>