• Rating uses a different set of Loads and Loads Combinations from the Design Mode

    MarcosBeier
    MarcosBeier
    The LBS users can utilize either the Design Mode or the Rating Mode . Therefore, the Rating Combinations are different from the Load Combinations and the Rating Loads can be dissimilar from the Design Loads . The user must initially select the Mode: Rating…
    • 29 days ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • 51. Flange rating in program does not match that in AutoPIPE Vessel's report, why

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Reporting Date Logged & Current Version July 2023 43.01.01.011 Problem: How to add a multiple saddle in horizontal pressure vessel? Example: …
    • 3 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Rating of Composite Steel Bridge

    Ana Carla Peres
    Ana Carla Peres
    RM > Analyzer > RateF schedule action evaluates the load rating factor for the bridge structure according to AASHTO code. Parameters necessary to be introduced are: Dead load: FactSWSUM.sup Live Load Sup: FactTraffic.sup Capacity: Steel PrimLC…
    • 5 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • OBM / RM Bridge

    Ana Carla Peres
    Ana Carla Peres
    1. OBM > Utilities > Send to RM Bridge 2. Select Standard Code and Material List 3. General Settings 4. Superstructure – Deck 5. Substructure – Cap , Piers and Piles 6. Substructure - Restraint Conditions 7. Assign RM Materials …
    • 5 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • OBD / RM Rating of Composite Steel Bridge

    Ana Carla Peres
    Ana Carla Peres
    Is presented below the Rating Factor calculation done in OBD / RM Bridge for a two spans composite steel bridge with a central pier. Bridge Modelling done in OBM and calculation performed in RM on a complete model in OBD. Table of Contents: A…
    • 5 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Rating of Composite Steel Bridge

    Ana Carla Peres
    Ana Carla Peres
    Rating of Composite Steel Bridge
    • Rating of Composite Steel Bridge.mp4
    • View
    • Hide
    • 5 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Files
  • "RateF" improved for Imperial Units

    Ana Carla Peres
    Ana Carla Peres
    In OBD CE 2021 Release 2 and RM Bridge v11.13 was improved “ RateF” schedule action for Imperial Units. “RateF”, evaluates the load rating factor for the bridge structure according to AASHTO code. This action is currently only applicable for steel and…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Rating - LFD Code - Calculation of K value.

    Dilip Matange [Bentley]
    Dilip Matange [Bentley]
    Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group- VM QUESTION: As per the LFD code when the rating of the beam is done, the output…
    • over 2 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Rating -- Bearing Location for Shear

    Dilip Matange [Bentley]
    Dilip Matange [Bentley]
    Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How to check the Rating at the Bearing location for Shear ? ANSWER…
    • over 2 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Rating for the Design Lane Load

    Dilip Matange [Bentley]
    Dilip Matange [Bentley]
    Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Is the program Rating for the Design Lane load ? ANSWER: Rating…
    • over 2 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Release Announcement: LARS Bridge CONNECT Edition X 64 (SES) V20.01.00.05

    Rahul Kalyankar
    Rahul Kalyankar
    LARS Bridge CONNECT Edition x64 V20.01.00.05 is now available for download on Bentley Software Downloads. LARS Bridge CONNECT Edition V20 is a modernized version of LARS using a completely new format and new capabilities. Please see the attached release…
    • LARS V20.01.00.05 Release Note.pdf
    • View
    • Hide
    • over 3 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Blog
  • How to Configure OpenPlant Modeler To Allow Flange Connection With Different Ratings.

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.07.00.32( Update-7) Environment: Windows 8.1/10 (64-bit) Area: Data Manager Subarea: Modeling Customization Original Author: …
    • over 1 year ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Release Announcement: LARS Bridge CONNECT Edition X 64 (SES) V20.00.00.32

    Rahul Kalyankar
    Rahul Kalyankar
    LARS Bridge CONNECT Edition x64 V20.00.00.32 is now available for download on Bentley Software Downloads. LARS Bridge CONNECT Edition V20 is a modernized version of LARS using a completely new format and new capabilities. Please see the attached release…
    • LARS Release Note - 06.26.2020.pdf
    • View
    • Hide
    • over 3 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Blog
  • How to Display Nozzle Rating and Facing on Continuation in AutoPLANT - OpenPlant Isometrics

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX(SS5) Environment: Windows 7/8.1 (64 bit) Area: Settings/Attributes Subarea: Schema- Custom attribute Original Author: Abhijit…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Rating Factor LEAP Steel program calculation

    Amber McCullough
    Amber McCullough
    Is the rating factor calculated by capacity divided by the applied load? I am getting rating factors less than one AND performance ratios less than one. That doesnt seem to make sense considering they are inverses of eachother. Unless the LEAP calculates…
    • Answered
    • over 5 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Attribute not shown

    Jyoti Patil
    Jyoti Patil
    Applies To Product(s): Exor MapCapture Version(s): 08.11.09.83 Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group …
    • over 3 years ago
    • ALIM | Exor
    • ALIM | Exor - Wiki
  • W2182-26: Pressure rating on mating flange to a valve is not the same at point xxxx warning message displayed in AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Warning Message Original Author: Bentley Technical Support Group Date Logged & Current Version June. 2017 11.00.00.22 Problem: The following warning…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Wafer Joint on Components with Different Facing and Rating Shows Error While Placement

    Deepak Singh
    Deepak Singh
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Properties Original Author: Harpreet Singh,…
    • over 5 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • RE: OPM SS6 - Connecting components of different rating

    Harpreet Singh
    Harpreet Singh
    Hi Tuan, Yes, it can be done in OpenPlant Modeler as well. You just need to modify the variable given in Project PCF file i.e. OPM_MATCH_PROPERTY_MAP_RATING Please refer below wiki article for this: http://communities.bentley.com/products/plant…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • How to Display Nozzle Rating and Facing Information on Connection & Continuation in OpenPlant Isometrics Manager

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX(SS5) Environment: Windows 7/8.1 (64 bit) Area: Settings/Attributes Subarea: Schema- Custom attribute Original Author: Abhijit…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • 05. Why Valve or Flange dialog drop down listings do not contain specific information (ex. Pressure Rating, End Connection, Manufacturer, Standard, Sub Category, Type, etc..) in an AutoPIPE model?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL Environment: N/A Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version Apr. 2016…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • RE: Pressure Relief Valves with different inlet / outlet pressures OPM v440

    Rahul Kumar
    Rahul Kumar
    Hello Grant, Yes you are correct. This is not currently supported. There is an existing enhancement for this. However on additional note we would like to request you to create a service request to get this logged to prioritize the issue. -Regards…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • To Query the Mating Components Based on Auto-Match

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • RE: DISPLAY OF RATING ONTO REPORT IN OPIM

    Rahul Kumar
    Rahul Kumar
    Hello Guy, Thanks to confirm. Yes, on every changes done in Schema, requires a proper closing of all running OpenPlant application. Sometimes user need to create a new i model as well to see the changes. This happens when modification has been done…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: DISPLAY OF RATING ONTO REPORT IN OPIM

    Rahul Kumar
    Rahul Kumar
    Hello Guy, Thanks for your query! Could you please attach the report file to investigate it at our end? Defining RATING attribute should work like described in wiki pages. I would suggest you to create a Service Request and attach all the relevant…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
>