• Perpendicular snap shows all elements out of plane after floating origin rotates. MicroStation V8i (SELECTseries 4)

    Christina Salmon
    Christina Salmon
    I am attempting to draw a line or measure a distance between 2 points using AccuSnap. I then select Perpendicular Snap which tentatively locks on to various Elements. As soon as I hover over a Reference Element (Circle, Text or Dimension, etc.) the Perpendicular…
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • File crashing and turning all levels invisible...

    Nathan Forbes
    Nathan Forbes
    Whenever Microstation V8i crashes it sometimes changes all levels in the file to an abstract level that is automatically renamed. It also changes all the elements to white (color 0). All of the levels the elements were previously on are now gone, and…
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • VBA Reference Attachment

    Peter Willmen
    Peter Willmen
    I have a vba script that attaches reference files using the 'ActiveModelReference.Attachments.AddCoincident' function. I need to modify it to work within the Projectwise environment but I am getting 'File not found' errors. The filename…
    • over 14 years ago
    • ProjectWise Programming
    • ProjectWise Programming Forum
  • Ignore Attachment, not working

    dario
    dario
    • over 12 years ago
    • MicroStation
    • [Archived] FileFormats Forum
  • Working in 3D with BA, help please.

    pjf
    pjf
    Hi all We are migrating from V82004+Triforma to V8I+architecture. To be short, i have already post some question there is two month and i'was ( and i'm) waiting for bentley's answer. In 2D we don't have many pb. We actually work with V8I in 2D but…
    • over 11 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • URG : Problems crossing TRIFORMA to Bentley ARCHITECTURE

    pjf
    pjf
    • over 12 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Re: Remove reference path for rasters

    Michael Farmer
    Michael Farmer
    Yes, that's correct as far as I know. But a temp security glitch meant that a user was able to mess about with our standards.cfg with: MS_DISALLOWFULLREFPATH = 0 MS_DISALLOWRELATIVEREFPATH = 0 which allowed the full path to be inserted. Horrors…
    • over 14 years ago
    • MicroStation Programming
    • [Archived] MicroStation V8i VBA Forum
  • Remove reference path for rasters

    Michael Farmer
    Michael Farmer
    Everyone, We have a problem that we have some files which have many "hard-referenced" raster files have been attached. I need to suppress the original location so that MS_RFDIR can supply the location. As an intermediate step, I am trying to change…
    • over 14 years ago
    • MicroStation Programming
    • [Archived] MicroStation V8i VBA Forum
  • Accessing an attachment's Element's Level in VBA V8i

    Jethro
    Jethro
    Dear All I have been struggling to use MIcrostation to get a referenced element's level properties in VBA: I first use ILocatePrimitive to locate only referenced elements to be located. I would then like the Element.Level…
    • over 14 years ago
    • MicroStation Programming
    • [Archived] MicroStation V8i VBA Forum
  • How do I use i Model?

    Lianh Winn
    Lianh Winn
    Hello. So I'm working on a project for my company and I need to submit an electronic copy of the project on a CD. The thing is the electronic file can only contain the dwg files, they don't want any images, tiff or other files on the CD. They don't…
    • Answered
    • over 10 years ago
    • MicroStation
    • MicroStation Forum
  • Activate Reference and trimming

    roenning
    roenning
    Currently it is not possible (?) to trim a line from activated reference A to a line from reference B. Snapping to points etc. in reference B when drawing elements is on the other hand allowed. I understand that " Only operations on the activated…
    • over 14 years ago
    • MicroStation
    • MicroStation Forum
  • [V8i] Reference levels batch processing

    jfennimore
    jfennimore
    We recently moved from MicroStation J to V8i SELECTseries 3 and we are finding out that after we convert the files to V8 format that the levels for our reference files are all turning off. I'm trying to create a batch process to allow me to set the "standard…
    • over 10 years ago
    • MicroStation
    • MicroStation Forum