• [CE U16 C#] Read all references (nested also) and their respective file location

    Ivan Nikolov
    Ivan Nikolov
    Dear Community, I am trying to read all references including the nested ones from a DGN file. However, I always end up with only first-level references and I can not go deeper. Here you can see one pice of code that returns only the first level references…
    • Answered
    • over 1 year ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • How do I change reference symbology properties in Bentley CONNECT Version14?

    Dean Romack
    Dean Romack
    I can't change the properties of my reference file even though I have full right to the file/
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • CONNECT Help: Reference Key-In Not Documented

    Jon Summers
    Jon Summers
    MicroStation Help has a page or two about Detaching References . However, the documentation fails to mention the key-in to detach all references: REFERENCE DETACH ALL .
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
  • Avoid Annotating Reference Objects

    Bruce Harper
    Bruce Harper
    OBD CONNECT I am trying to annotate beams in my active model, but the annotation rule is also capturing the beams in a referenced model too, I do not want to annotate these. I tried making a Selection Criteria, which is Family & Part = Steel Beams…
    • over 2 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Open master file without references

    Yvonne Lohse
    Yvonne Lohse
    Product: MicroStation Version: V8, XM, V8i, CONNECT Environment: N\A Area: Reference Subarea: N\A Problem Open master without references. How is it possible to open a master file without attached…
    • over 3 years ago
    • MicroStation
    • MicroStation Wiki
  • AECOsim CEU4 Reference Live Nesting - strange behavour

    JoeyJM
    JoeyJM
    Hi All, My file has four references in one of my files all of which have live nesting turned off. However, references are being nested in two of the references. I've never seen this in V8i. What could be causing this? Has anyone else experienced…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Nesting issue with MS Connect°

    Duncan Gammie
    Duncan Gammie
    I am finding issues with ms connect and nested references. For example: 1. When limiting nesting level to say 1, all nested references within files further down are shown and will not turn off. or if they do, return on reopening the file ie I cannot…
    • over 8 years ago
    • MicroStation
    • MicroStation Forum