Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Report
Date Logged & Current Version
Oct 2023 23.00.00.230
Problem:
In the text output, as part of each stress summary, results are given at each node,…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reporting
Date Logged & Current Version
Oct 2023 23.00.00.230
Problem:
In some of the fatigue results, I am seeing high CUF values, which seem contrary…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reporting
Date Logged & Current Version
Oct 2023 23.00.00.230
Problem:
In a model set up Service Level A and B summaries. For equation 10, the Service Level…
Answer:
As of Oct 2023, there frequency is not being reported. Instead the Period is reported. The period was chosen because it is used to determine the acceleration.
Please create a model with seismic load case, analyze, and review results. Find…
Product(s):
OpenRoads Designer
Version(s):
10.00.00+
Area:
Report
Question
Is it possible to Embed Civil Reports output within the drawing?
Answer
Save the report as xlsx and open it.
Select the cells that you want…
Hello,
I am using a OpenRail 2022 Release3.
I am prepearing a Point Station Offset Elevation Feature Report.
I want to insert a additional column with information "Rotation Offset", that The Point cointains.
Is there a possibility to do so?
…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reports
Date Logged & Current Version
Aug 2023 23.00.00.230
Problem:
The following occurs when printing an output report, Page breaks causes data associated…
When I create a Property Definition using the Items Types function, with an expression to calculate the length of an object, it is neatly displayed in the details window. However, when I try to generate a report from this, different values are suddenly…
Is there a way for AutoPipe to determine the total length of a model? If there is I must be totally missing it somewhere. Any clarification is appreciated.
All the best,
Jeff
I am working on one-way slab supported by mild reinforced concrete beams. The beam is trimmed as a T-section with flange width of 99". I drew #4 at 18" (full slab area) on top of the slab in the direction parallel to the beam, which make 5-#4 (total As…
Hi all, I'm trying to get component reports for a road design. Below is a screenshot of the component Quantities generated from the corridor reports tool.
This looks like it has captured all the different types of material I was expecting to see for…
Hello,
As I was proceeding through a design of steel with some concrete support elements, I noticed an odd discrepancy when I attempted to pull out the load envelopes using the report functionality v. the view on screen functionality in the Output…
Product(s):
MicroStation
Version(s):
10.17.xx.xx
Environment:
N\A
Area:
Properties
Subarea:
Report
How to build a Sheet Index Report and filter by folder name.
Background
From User... How…
Product(s):
OpenBuildings Designer
Version(s):
CONNECT Edition & V8i
Area:
Import / Export
Subarea:
Reports
Problem Description
I have created a new report definition and I want to share it with other…
RAM Elements 2023 Release Notes – Updated April 2023
Features :
1. Update AS 4100-1998 to AS 4100-2020 Australian steel design code. The update includes the Beam Design and Truss Design modules.
Figure 1. New Australian AS 4100-2020 steel design…
Applies To
Product(s):
STAAD.Pro
Version(s):
All
Environment:
N/A
Area:
STAAD,Pro Support Solutions
Subarea:
STAAD.Pro Postprocessing workflow
Original Author:
Bentley…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reports
Date Logged & Current Version
March 2023 23.00.00.230
Problem:
How to generate a report on only a portion of the model using Report Manager in AutoPIPE…
Applies To
Product:
AutoPIPE
Severity:
High
First Affected Version:
11.04
Fixed and Released in Version:
12.08.00.063
Title
Max Ratio for flange with ANSI check is displayed incorrectly in…
Example:
The +1, +2, are typically associated with soil points that occur between actual node point of the model.
Example:
In the image above A05 F is the far point of a bend, and +1, +2, etc.. are soil points spaced as defined on the Soil tab…
My item types are set up perfectly. I have used the expression builder to 'concatenate' variables and text so it the item's name is in the format I need.
This is the set up:
I need the length for element 1, and I need the part number, ABC/ in front…
Hi,
I have completed several models in AutoPIPE and have noticed that the most recent .sqo output file I created for a model lists results by load case. For example:
Previous models list results grouped by node. For example:
I have tried…
Hallo zusammen,
ich habe ein Problem bei der Erstellung eines Reports.
Gezeichnet habe ich verschiedene Platten (Balken) mit dem selben Querschnitt (6cm x 12cm), aber unterschiedlichen Längen. Dann habe ich per Objekttypen, Informationen an einige…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Modeling
Date Logged & Current Version
Jan 2023 12.08.04.009
Problem:
How to test if a branch pipe is actually connected to a header pipe while using AutoPIPE…
Hi
Could someone advise on the best method to report vertical offsets from an alignment to a terrain model, at a chosen station interval?
Thanks