• 05. Thermal loading does not seem to be applied in the axial direction in AutoPIPE model, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE, Version(s): All Environment: N/A Area: Settings Original Author: Bentley Technical Support Group Problem: In my simple model…
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02. What value should be entered into the "No. of thermal ranges" setting in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: What value should be entered…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. AutoPIPE shows a code combination labeled ‘Max Range’ as an expansion case…what is this?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: …
    • 9 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 04. Is there more information available on modal analysis in an AutoPIPE output report?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Dec. 2016 10.01.00.09 Problem: …
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. Should ZPA be applied when performing a Dynamic analysis with AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Dec. 2016 10.01.00.09 Problem: …
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02. Why do the acceleration values need to be multiplied by 25.4 in AutoPIPE's output report?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Dec. 2016 10.01.00.09 Problem: …
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. Under the Missing Mass Combination drop down listing in an AutoPIPE model, only the SRSS and Absolute SUM method appear as choices. Where is Modal?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Dec. 2016 10.01.00.09 Problem: …
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01.h.01 - Detail explanation of the Code Compliance settings in the Analysis Summary section of AutoPIPE's output report

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i, CONNECT; Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02-05. Model Options> Results - AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Select the link below for Q&A on the following Tools> Model Options> Results settings in AutoPIPE: Model Options> Result: Format (Node/Combin) Displacement Scale Force (Global/Local) Range reduction factor Include axial force…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "Force (Global/Local)" setting in AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Comments, Questions, and Answers related to Model Options> Results> "Force (Global/Local)" setting in AutoPIPE: Item #1: Can you confirm that my understanding of global/local axes is correct with respect to the listings of coordinates in output files…
    • 10 months ago
    • AutoPIPE
    • AutoPIPE Wiki