Title : Coffee Corner: Geotechnical Analysis - Getting PLAXIS Calculation Results Presenter : Micha Van der Sloot, Senior Manager User Success - Geotechnical, Bentley Systems, Inc Date and Time : October 12, 2021 at 10:00 am AND 4:00 pm CEST
Register…
In the results ribbon -> Reports -> Section Forces:
If you set your sorting options and loading options, you can save this report. Then you can later add it to your Postprocessing: Reports (the report that you print). Once you hit "OK" the report will…
For RM Bridge any Finite Element Model three-dimensional bridge is an extension of the normal parametric beam model. Therefore, despite the additional input required to create the FEM bodies and store results, also some additional output is usual for…
The Plot Container stores all Plot profiles with common definitions to create several results graphic plots. As shown in the image below, the upper list has all Plot Containers with plot definitions of the same type while the bottom list has the plot…
In this sub-menu users can find the necessary functions for creating plot files presenting results and the geometry of the structural model.
Directory : Selection of the directory, where the plot files or plot profiles for creating the plot files…
In RM Bridge : Analyzer \ Results users will find a menu that provides functions for displaying and evaluating results of the calculation and any interesting intermediate results. For example, curves describing the actual creep and shrinkage behavior…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reports
Date Logged & Current Version
July 2021 12.06.00.48
Problem:
How to estimate which mode is the most important from AutoPIPE's Modal Analysis results…
When I try to view the reaction results some of the boxes are off the screen and so I can't drag them back on.
How do I bring these boxes back onto the screen?
Zooming out and changing the position of the origin doesn't change their position.
Thanks…
Applies To
Product(s):
AutoPIPE Nozzle
Version(s):
V8i
Area:
Report
Original Author:
Bentley Technical Support Group
Date Logged & Current Version
July 2021 08.11.08.36
Problem: …
Background: I am a consultant specializing in water distribution modeling and have been using both WaterGEMS and InfoWater regularly for 9 years. I am therefore, very familiar with the strengths and weaknesses of both platforms. All of these requests…
Product(s):
SewerGEMS, CivilStorm
Version(s):
CONNECT Edition
Area:
Calculations
Problem
When using the Elevation-Area method to define a pond, the results are drastically different as compared to using the Elevation-Volume…
Product(s):
Bentley SewerGEMS, CivilStorm
Version(s):
V8i, Connect Edition
Area:
Output and Reporting
Problem
Why don’t I see the results for the LID element, even though Detailed Results under output options in LID properties…
New in PLAXIS 2D/3D Output Viewer CONNECT Edition V21 Service Release 1
Release: February 2021
The PLAXIS 2D/3D Output Viewer CONNECT Edition V21 contains the following improvements and updates compared to PLAXIS Output Viewer CONNECT Edition V20…
RAM Concept’s load history deflection calculations are complex due to the many non-linear behaviors that are considered (see Load History Deflection Calculations for more information). When unexpected results are obtained, it can be difficult to verify…
RM View post-processing tool creates a .DGN file with the selected results from the RM Bridge Enterprise database. Please watch the video below: RM Bridge View - General overview : 2 minutes video
Analyzer is the analysis component of RM Bridge Enterprise CONNECT Edition , here users can work on the models Properties, Structure, Construction Schedule with Stages and Activations and Results.
While in OpenBridge Modeler or in the Modeler section…
Hi I use STAAD Pro Connect V22 Update 3. Here I display a color plot of stresses in a plate between girders. I get Von Mises stresses more than twice as large as the Tresca stresses. How can this be? In theory Tresca shall be equal or larger than Von…
Application
PLAXIS 3D
Version
Technology Preview PLAXIS 3D CONNECT Edition Update 4
Date created
08 October 2020
Date modified
08 October 2020
With the release of PLAXIS 3D CONNECT Edition Update 4 (20.04), new…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Results
Date Logged & Current Version
Sept 2020 12.04.00.13
Problem:
In the harmonic analysis, the force is input as an amplitude, for example 100N,which…
Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD
Version(s):
10.02.XX.XX and later
Area:
Modeling
Introduction
This article explains how to visualize cross section results graphically. This feature is available in CONNECT…
Hello, I hope somebody could help me.
Regarding the example, I'm comfused, becuase the example that is included in the software "AP50SR2" has a Force at the elbow end.
I followed the steps "Executing Steam Relief Example (ap50sr1)", and I don't…
Dear all (and Geoff),
I have just upgraded to Connect v14 from 5.7, so forgive me if I'm missing something obvious.
I am estimating the stiffness of a structure based on some support conditions. In Postvue I usually begin to review my results using…
Hello,
Does HAMMER provide options to display symbols of model elements (pumps, tanks) along the transient profiles? Also, how can I customize labels to only show a select few?
Regards,
Youssef
When using one version of AutoPIPE Vessel or MicroProtol the results do not match the if the same exact model is run in another version of the software. This WIKI page aims to answer why that is:
Item #1:
The tube sheet calculations were not the same…
Hi,
I am currently working on a dynamic modelling project in PLAXIS where we are obtaining the lateral earth pressures on a gravity retaining wall.
The retaining wall is modelled as a linear elastic material.
To export the results, I have preselected…