Application
PLAXIS 2D
Version
PLAXIS 2D 2023.1
Date created
07 March 2023
Date modified
07 March 2023
Since the release of PLAXIS 2D 2023.1, PLAXIS 2D offers a new right mouse button context menu option called…
Hi,
I'm trying to rename segment, but could not find such option. Reordering and renumbering doesn't provide solution in my case. The problem is following:
I'm working on a project with extensive installation, which is separated to smaller physically…
Modeler Main Girders are in general the superstructure elements created with longitudinal segments using as reference axis the road alignment or a local simplified version of it. They can be referenced to the Base Segment or Point Segment and have additional…
The EC classes mentioned here refer to those found in two EC schemas delivered with MicroStation...
Base Element Schema ( BaseElementSchema.01.00.ecschema.xml )
DGN Element Schema ( DgnElementSchema.01.00.ecschema.xml )
A DGN Line Element has…
I'm importing PCF files generated in Plant 3D, and trying to associate the line number with the segment.
I first tried to add a custom attribute of MISC-SPEC1 to the PCF file using Plant 3D's iso.atr ("MISC-SPEC1 LDT.PipeTag"). I believe this doesn…
Hi,
i have question about the direction of force & moments. The pipe force-moments output will have same direction (whether positive or negative) as the pipe displacement at a node or not in Autopipe? i have checked and sometimes the direction between…
"Ross Sinclair" wrote in message news:48e9ca69@news.prod-bent.dmz...
When are we likely to see the AutoPIPE 9.1 release with these new features:
new commands to renumber, reverse and join segments
Ross Sinclair
If a segment seems to become uneditable, it may be due to data 'hiding' on a different segment. To manage the data, go to the element inspection form either on the asset or within the report, as applicable.
If there is more than one segment, Segment…
Product(s):
WaterGEMS, WaterCAD
Version(s):
08.11.XX.XX and later (features vary)
Environment:
N\A
Area:
General
Problem
When computing a criticality analysis, which uses the Scope Type "Subset", there…
(Posted on behalf of Be Communities member)
InRoads V08.11.07.566
I am having a problem using the command File > Import > Geometry > From Graphics to import a horizontal alignment. The first curve imports as a series of short segments rather than…
Hi,
I am running the latest version of Autopipe (select series 2) and have hit a snag.
I created a model in the previous version, I have not run out of segment names and I thought i was OK on the Node count as well, but when I go to analyse the…
Dear Sirs,
While defining the time history load in Staad Pro, how can we arrive at the values of "time", "acceleration" and "arrival time" for a particular seismic zone? Are these values same for the all seismic zones?
Do we have to calculate…
Dear All,
After PXF import from autoplant into autopipe each segment is automaticly assigned to a pipe, based on the linenumber in autoplant. So far no troubles, but when it comes to defining a wind load I have some problems. You can only define…