• How to control Support Locator on Piping isometric BOM

    P Manoj Kumar
    P Manoj Kumar
    I have used support locator for specifying a resting support (Pipe just resting on steel), and wanted to get this information on isometric BOM. But the result show that the locator support information is coming in SHOP BOM, i wanted it on Field BOM…
    • over 2 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • How to use Isometric Custom Symbol for Dummy Leg /Trunnion Support & How to include them under Supports Section of Bill of Material

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.294 (SS6Refresh4) & above Environment: Windows 7/8.1/10 (64-bit) Area: Settings/Attributes Subarea: Modifying Symbol Original Author…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Group Supports Using Common Tag Name

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Configuring the BOM and Reports…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Change the Cell in the OpenPlant Isometrics Manager for Base Support

    Swapnil Joshi
    Swapnil Joshi
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Modifying Symbols Original Author: Swapnil Joshi…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • RE: How to create second line for information in BOM on isometric

    Rahul Kumar
    Rahul Kumar
    Hi Richard, Please create Service Request and attach relevant files like an intermediate file, Report.def file to investigate the issue. -Regards | Rahul Kumar
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: OpenPlant Isometric Manager does not update distances to supports

    Harpreet Singh
    Harpreet Singh
    Hi, Can you attach the images again? Also confirm the product you are using OpenPlant Isometrics Manager with? Is it AutoPlant Modeler or OpenPlant Modeler? What are the versions you are using? Regards, Harpreet
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: Combining supports types in OPIM BOM

    Rahul Kumar
    Rahul Kumar
    Hello Richard, Use below wiki article for reference. http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/26531.grouping-of-supports-based-on-common-ec-class-name Also check other related wiki for…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • To Hide supports in OpenPlant Isometrics Manager

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 Environment: Windows 7 (64 bit) & others Area: Settings/Attributes Subarea: Original Author…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • To Display UNIT information for Support in BOM for OpenPlant Isometrics Manager

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 (SS6) & 08.11.09.574 (SS5) Environment: Windows 7( 64 bit) Area: Settings/Attributes Subarea: BOM report…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Label Pipe Support Tag

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support Group…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • To Display Support Orientation in OpenPlant Isometrics Manager

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Round Off Values After Decimal For Support Co-ordinates

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Grouping of Supports Based on Common Tag Name

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Configuring the BOM and Reports…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • OpenPlant Isometrics Manager SS5 build 278 Insulation

    Carpsy
    Carpsy
    Good day, I would like to disable insulation on the generated isometric manager without the user having to deal with this level in MicroStation. Is this possible? Ken
    • over 9 years ago
    • OpenPlant | AutoPLANT