• print loads for selected supports

    eswara gollapudi
    eswara gollapudi
    I want to print support loads at selected supports only. How do I do that using results grid?
    • 10 months ago
    • AutoPIPE
    • AutoPIPE Forum
  • What difference between support load/displacement and displacement?

    OTTAP CP
    OTTAP CP
    Hello, I just found that the displacement in results between support load and displacement is the same at the point where has the guide support with a gap. I notice it in GRTP case. That means whether the support and the pipe move together, However…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Forum
  • 13. Why are spring or rigid hangers on vertical legs showing large reaction loads in the Hydrotest load set case for AutoPIPE's reports?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Reporting Date Logged & Current Version Sept2020 12.04.00.13 Problem: Why are spring or rigid hangers on vertical legs showing large reaction loads in the…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 12. Support Forces Report, why do local support forces on a global axis not match global forces in AutoPIPE's output report?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version April 2020 12.03.00.17 Problem: Support Forces Report, why do local support forces on a global axis not match global…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Input local axis and output of restraint reaction in global

    Sridhar N
    Sridhar N
    we want local and global axis are same required. Auto pipe input in one axis output one axis both comparison very difficult. In Caesar input and out put are same axis. As per Auto pipe analysis output report axis are indicated in isometric as per that…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Forum
  • Q. Rigidly supported pipe indicates vertical movement down during load case, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version June 2019 12.01.00.10 Problem: Pipe rigidly supported indicates vertical movement down during load case, why? Example…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 04. What is the difference between the Support and the Restraint output reports in AutoPIPE?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: reports Original Author: Bentley Technical Support Group Date Logged & Current Version May 2015 09.06.02.06 Problem…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 05. Which AutoPIPE sub-report should be provided to the Structural Engineer to size the anchor: the Support forces or Restraint Reactions report?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version May 2015 09.06.02.06 Problem…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. What is the difference between the support and the restraint output reports in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02. Why are Membrane or Local stresses from pipe supports not included in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. During animation of load-case in AutoPIPE, pipe support moved with pipe freely without any opposition, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): All Area: Results Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem: When…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 04. Support report indicates a load on a support who's open gaps never closed during an AutoPIPE Analysis, so why is there a load on the support in open gap direction?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem: When reviewing…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 05. Support results on a vertical support in an AutoPIPE model does not change, regardless of "Weight of Contents" settings. Appears Weight of Contents is not considered in my model, how to verify?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 06. AutoPIPE FAQ Question 116: Why are membrane stresses from pipe support not included in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version June 2015 09.06.02.06 Problem…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. Gravity + Thermal + User load cases added together give incorrect Restraint Report results in AutoPIPE, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Area: Report Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: To summarize, I have…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 06. Gravity + Thermal + User load cases added together give incorrect Restraint Report results in AutoPIPE, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE, Version(s): ALL Environment: N/A Area: Reports Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "Support" sub report using Results> Output Report in AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Comments, Questions, and Answers for Support sub-report using Results> Output Report in AutoPIPE Item #1: Difference between the Support and Restraint output reports Item #2: Membrane stresses at pipe supports are not reported Item #3: During animation…
    • 7 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "Support"- Model Input listing sub-report in AutoPIPE

    JamieP
    JamieP
    Comments, Questions, and Answers related to Model input listing: Support sub-report: Item #1: How to export support node points coordinates from AutoPIPE to Excel ? To watch the on-demand webinar "Maximizing AutoPIPE Standard and Custom Reporting…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 10. How are a support's axial force due to xxx load case calculated in AutoPIPE's reports?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Original Author: Bentley Technical Support Group Date Logged & Current Version April. 2017 11.00.00.22 Problem: How are supports axial force…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 09. Support forces for Occasional load (i.e. Earthquake) are not evenly distributed among multiple supports in AutoPIPE model, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Original Author: Bentley Technical Support Group Date Logged & Current Version April. 2017 11.00.00.22 Problem: Support forces for Occasional…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • RE: How to get global direction of support gaps in report?

    Mike Dattilio
    Mike Dattilio
    Hello Gobinath, You are correct that the model input listing Support Data Listing sub-report has 2 columns labeled Gap 1 and Gap 2: The user can look to the component listing for greater details on the support direction. Remember that the…
    • over 6 years ago