• Waterlevel inspection and editing in PLAXIS 2D

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Version PLAXIS 2D 2015 Date created 09 July 2014 Date modified 09 July 2014 Since PLAXIS 2D AE, (user-defined) water levels are created as a series of water level segments. However, this makes…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Workflow of PLAXIS 2D - 04: Water conditions

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Version PLAXIS 2D AE Date created 20 February 2014 Date modified 20 February 2014 In this movie, we will focus on the fourth mode of PLAXIS 2D: the Water mode. In this mode, you can define…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Permeability value change not stored when changing from From data set to None [Solved]

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Issue status Solved First Affected Version PLAXIS 2D 2017 PLAXIS 3D 2017 Found in Version PLAXIS 2D 2017 PLAXIS 3D 2017 Fixed and Released in Version PLAXIS 2D CONNECT Edition V20 Update…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Pore pressures in interfaces may be incorrect with Interpolate pore pressures

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2015.00 Found in Version PLAXIS 2D 2015.00 Fixed and Released in Version PLAXIS 2D 2015.01 Issue # 23112 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • External waterloads on a structure may not be correct in a flow calculation

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Issue status Solved First Affected Version PLAXIS 2D 2010.01 PLAXIS 3D 2012.00 Found in Version PLAXIS 2D 2010.01 PLAXIS 3D 2012.00 Fixed and Released in Version Solved in a recent version…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Interpolate pore pressures with an inclined top cluster boundary does not work correctly in 2DAE.00

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D AE.00 Found in Version PLAXIS 2D AE.00 Fixed and Released in Version PLAXIS 2D AE.01 Issue # 20836 Date created 26 February…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Water weight only updated in the initial phase

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010.01 Found in Version PLAXIS 2D 2010.01 Fixed and Released in Version PLAXIS 2D AE.00 Issue # 17798 Date created 28…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 3D2011.00 Groundwater flow does not take the volume-dry-setting into account

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status Open First Affected Version PLAXIS 3D 2011.00 Found in Version PLAXIS 3D 2011.00 Fixed and Released in Version Issue # 14968 Date created 30 June 2011 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D2011.00: Default pore pressure calculation is taken from the previous phase instead from the parent phase

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2011.00 Found in Version PLAXIS 2D 2011.00 Fixed and Released in Version Issue # 16034 Date created 02 January 2012 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Updated mesh + updated water pressures for deactivated clusters beneath general phreatic level gives wrong external waterloads

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2011.00 Found in Version PLAXIS 2D 2011.00 Fixed and Released in Version PLAXIS 2D2011.02 Issue # 17181 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D2011: (External) water loads wrongly applied during safety and dynamic calculations

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2011.00 Found in Version PLAXIS 2D 2011.00 Fixed and Released in Version Issue # 16342 Date created 02 January 2012 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Borehole water settings in calculation phases

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status Open First Affected Version 3DFoundation 2.2 Found in Version 3DFoundation 2.2 Fixed and Released in Version Issue # 8157 Date created 20 May 2009 Date modified…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Anisotropic permeability in 3D 2011 groundwaterflow gives incorrect results

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D 2011.00 Found in Version PLAXIS 3D 2011.00 Fixed and Released in Version Solved in a recent version Issue # 16109 Date…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D2010: (External) Water loads on plates coming from inactive clusters

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Open First Affected Version PLAXIS 2D 2010 Found in Version PLAXIS 2D 2010 Fixed and Released in Version Issue # 15292 Date created 02 December 2011 Date modified…
    • over 2 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Consolidation TPP: Activating a cluster and changing its water conditions

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010 Found in Version PLAXIS 2D 2010 Fixed and Released in Version PLAXIS 2D AE Issue # 15911 Date created 12 October…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Transient groundwater flow analysis is reset to steady state after changing the calculation type

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010.01 Found in Version PLAXIS 2D 2010.01 Fixed and Released in Version PLAXIS 2D 2011.00 Issue # 14642 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Unable to activate interfaces in water conditions mode for Undrained B materials

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010.01 Found in Version PLAXIS 2D 2010.01 Fixed and Released in Version PLAXIS 2D 2011.00 Issue # 14503 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • 2D: cannot delete a closed flow boundary

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2010 Found in Version PLAXIS 2D 2010 Fixed and Released in Version PLAXIS 2D 2011.00 Issue # 14675 Date created 10 June…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki