• WaterGems VSD Pumps in Parralel and error message 41797

    sean keown
    sean keown
    I am using Watergems V8i series 3, and trying to model a pump station with two identical VSD pumps in parallel. When I set the pumps up in parrallel, i.e. by just making them have a common node on either side of the pumps, the system balances but only…
    • over 10 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCad Select Series 2 Copy Graph Data Problem

    trout0915
    trout0915
    I am having problems with copying data from the graph data tab. My problem is that when I copy all the data the header row is not copied. So when I paste in excel I have no idea what the data in each column represents. This woudn't be a problem if WaterCad…
    • over 12 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: Darwin Calibrator

    Martin Pflanz, P.E.
    Martin Pflanz, P.E.
    Didi, can you help out with some clarification on your question, are you working out a workshop and trying to get the results that are part of the workshop? or Calibrating using Darwin Calibrator for an actual system? If you are Calibrating for a real…
    • over 15 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCAD for Reclaimed Water

    bwhite
    bwhite
    Any suggestions on how to model a reclaimed water system that delivers water to multiple (bulk) storage ponds? Each pond has a level control and a pressure staining valve. Is there a way to simplify this model, I can't justify trying to model all the…
    • over 11 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterGEMS - Variable Speed Drive

    suminda79
    suminda79
    Dear Bentley I am trying to Model a VSP pump and I am using WaterGems V8i (Select Series 3) I want to model a a situation where I got a pump which is greater than the required capacity . So I am planning on using a variable speed system to reduce…
    • over 12 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCad Select Series 2 Unidirectional Flushing - No Option for Pressure Constraint

    trout0915
    trout0915
    The newer version of WaterCAD Select Series 2 seems to have removed the option to specify a pressure constraint for flushing alternatives. I don't know when this was removed, but for me it would be very useful to specify a pressure constraint. The…
    • over 12 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Reporting the Physical Properties of a Junction

    giazax
    giazax
    Hi All, i'm writing a C# code using WaterObjects.NET to report for every junction its Physical properties : (elevator, areas, emitter coefficent). Which classes/feaures may help me? For example from the programming manual i found that scenarios…
    • over 10 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum