• SIG Virtual Workshop: OpenFlows - Creating District Metered Areas to Better Manage Water Systems

    Kelly Fox
    Kelly Fox
    Title: SIG Virtual Workshop: OpenFlows - Creating District Metered Areas to Better Manage Water Systems Date/Time: June 18, 2020 11:00 A.M. EDT Presenter: Tom Walski, Bentley Fellow, Bentley Systems, Inc. Register Now This OpenFlows Special…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How Water meters will conserve daily use of water

    manju armulla
    manju armulla
    Watflux are global leaders in manufacturing of Water Meters, Digital Water Meters, Domestic household water meters, Intermittent water meters, Manual water meters, Residential water meters. Water meters are essential to a utility for a few reasons: They…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How to model discharge to atmosphere point

    Mohamed Khaled
    Mohamed Khaled
    HI, I'm working on my college project (The project is a plumbing system to drain a 1-m3 tank in the shortest time ). I use the discharge to atmosphere element at the end of the project but I'm really confused with this element's input data like [Flow…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Tank and end connections

    Allam Dinesh Reddy
    Allam Dinesh Reddy
    Hi, How to draw a pipe layout . The case is "a Pump pumps in water from a underground tank to a tank on a building". Now as in water cad we insert a tank on the building and connect it to a pump and inturn connects to the U/G tank. BUT we have to provide…
    • over 10 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: Darwin Calibrator

    Martin Pflanz, P.E.
    Martin Pflanz, P.E.
    Didi, can you help out with some clarification on your question, are you working out a workshop and trying to get the results that are part of the workshop? or Calibrating using Darwin Calibrator for an actual system? If you are Calibrating for a real…
    • over 15 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • SewerCAD/GEMS and SCADA Connect

    Bill Prassas
    Bill Prassas
    Hello everybody, Does anyone knows if SewerCAD/GEMS supports connection with data of a SCADA system through SCADA Connect? Thanks Bill Prassas
    • over 11 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCAD for Reclaimed Water

    bwhite
    bwhite
    Any suggestions on how to model a reclaimed water system that delivers water to multiple (bulk) storage ponds? Each pond has a level control and a pressure staining valve. Is there a way to simplify this model, I can't justify trying to model all the…
    • over 11 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCAD age calculation fails

    tschrage
    tschrage
    I have run into a recent problem. I've been trying to do a age calculation on our water system and for some reason the largest duration I can calculate is 128 hrs. If I change it to 129 hrs the calculation fails and I get an error: Calculation Engine…
    • over 10 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Average Demand Calculation and Fire Flow

    Mayowa
    Mayowa
    My model is fine and everything works fine however the design criteria for demand is 2.1 multiply by the average demand + Fire Flow (as indicated in the snapshot) I have setup the Scenarios and alternative for this criteria based on the BASED DEMAND…
    • over 9 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCad Select Series 2 Unidirectional Flushing - No Option for Pressure Constraint

    trout0915
    trout0915
    The newer version of WaterCAD Select Series 2 seems to have removed the option to specify a pressure constraint for flushing alternatives. I don't know when this was removed, but for me it would be very useful to specify a pressure constraint. The…
    • over 12 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Reporting the Physical Properties of a Junction

    giazax
    giazax
    Hi All, i'm writing a C# code using WaterObjects.NET to report for every junction its Physical properties : (elevator, areas, emitter coefficent). Which classes/feaures may help me? For example from the programming manual i found that scenarios…
    • over 10 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterCad Select Series 2 Copy Graph Data Problem

    trout0915
    trout0915
    I am having problems with copying data from the graph data tab. My problem is that when I copy all the data the header row is not copied. So when I paste in excel I have no idea what the data in each column represents. This woudn't be a problem if WaterCad…
    • over 12 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum