• Analysis of LNG Tanks Using Potential-Based Fluid Elements

    Juan Trueba
    Juan Trueba
    Analysis of LNG Tanks Using Potential-Based Fluid Elements In civil engineering design and analysis, the effects of fluids on the motion of structures can be very important. This is particularly true in seismic analysis of liquid storage tanks. In this…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • FSI Analysis of a Hydroelectric Power Plant

    Juan Trueba
    Juan Trueba
    FSI Analysis of a Hydroelectric Power Plant Hydroelectric power plants are used for economic and environmentally friendly electric power generation all around the world. One of the technical challenges in the design of such structures is to consider…
    • 7 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • MOVING HYDRANTS IN WATERGEMS

    Newman Bailey
    Newman Bailey
    I have set up a watermodel with my water main, hydrants, and services from each home. If the layout of my hydrant has changed, is there a way to shift these without deleting everything I have setup? When I try to drag and drop them it messes up my watermain…
    • 10 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WATER GEMS UNIT DEMAND AND PEAK FACTOR

    Newman Bailey
    Newman Bailey
    Typically in a residential subdivision in Alabama we have been using a unit demand (per residential home) of 350 gpd (.24 gpm). I was always taught to use a peak factor between 2-3 so 2.5*.24 gpm=.60 gpm per residential home. Is this overly conservative…
    • 11 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Publication for systematically troubleshooting closed gate valves in a city water distribution system.

    Edward Boucher
    Edward Boucher
    1st time use of this resource... I am in search of a publication for systematically troubleshooting/finding closed gate valves in a city water distribution system. I have been attempting to do this using the change in pressure from static to residual…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How to save some automatically created element to a library of feature definition? Model Builder / Water Segment

    Ignacio Weiler
    Ignacio Weiler
    I imported some conduits from model builder, and it has created automatically few water nodes with a 3D good looking. I intend to move those created nodes (as shown in the picture below) to a library and make them able to manage with the feature definition…
    • over 1 year ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • Bentley Webinar: Demystifying Water Infrastructure Operational Digital Twins

    Douglas Miranda
    Douglas Miranda
    March 29, 2022 11:00 AM to 12:00 PM Eastern Time (US & Canada)
    Online
    Title: Bentley Webinar: Demystifying Water Infrastructure Operational Digital Twins Date: Tuesday, March 29, 2022 Time: 10:00 AM Central Daylight Time Duration: 1 hour Link to Register: https://event.on24.com/wcc/r/3711112/7D4DB108C90EAB08DA05646545822D3C...
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Calendar
  • Links for Technical Videos available in Bentley Structural YouTube Channel

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): CONNECT Edition Environment: ALL Area: Webinars, Events and Videos Subarea: Original Author: Abhisek Mandal, Bentley Technical…
    • 12 hours ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Context Capture Constraint options greyed out.

    Karyn McDonald
    Karyn McDonald
    Hi, I would like to use the contraint options for editing a surface with a water body except the contraint options are greyed out. Any idea why? Thanks very much
    • over 2 years ago
    • ContextCapture | Descartes | Pointools | Orbit
    • ContextCapture | Descartes | Pointools | Orbit Forum
  • Partially Closed Valves in water supply system

    levon batoyan
    levon batoyan
    Hello, I'm modeling a high pressured water supply system full of partially closed valves (which people use as some kind of "prv's" to reduce pressure because they don't have enough money to buy it). The information they gave me is D(mm) of a valve,…
    • Answered
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Some pipes are removed after importing from dxf

    Sebastián Seminario
    Sebastián Seminario
    I am trying to import 2 dxf files containing a set of lines through ModelBuilder. When I imported the first one, the network is correctly created with pipes corresponding to each line and joints are automatically created to connect pipes. However…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • STAAD_Clarifier Modelling Tool

    Kush
    Kush
    (You must be signed in to download this file) The Clarifier Modelling Tool can help to overcome the challenges in modelling Clarifiers (or Clariflocculator Tank) in STAAD.Pro CONNECT Edition. Some of the important features of this tool are listed here…
    • Clarifier Modelling Tool_V2.2.vbs
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD API Solutions
  • "Lateral has a customer meter as its stop node" User notification

    Chetan Topre
    Chetan Topre
    Hi, I am using Bentley Connect Edition 10.01.01.04. I used modelbuilder for importing the taps, laterals and customer meters. Using tools, the taps were assigned to the links. For laterals, I am getting user notification as "Lateral has a customer…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Fluid - PLAXIS UDSM

    Felipe Fonseca
    Felipe Fonseca
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D CONNECT Edition V21 PLAXIS 3D CONNECT Edition V21 Date created 25 January 2021 Date modified 25 January 2021 With the release of PLAXIS 2D/3D CONNECT Edition V21…
    • 11 months ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Change Groundwater Level after Phase4

    Jeremy Kuelling
    Jeremy Kuelling
    How can I change the Groundwater level after a few Phases in Plaxis 3D? I defined the groundwater level with the head in the borehole at the beginning of the model. How can I change it in the construction stages? Probably I have to install a well…
    • over 2 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Forum
  • OpenPlant P&ID - Water/Wastewater Symbols

    Daniel  Cook
    Daniel Cook
    I am new to Bentley OpenPlant Software, and we are working on a new Wastewater Treatment Plant. I was wondering if there was a Bentley cell library that includes more symbology for Water/Wastewater related items such as headworks, UV, grit collectors…
    • over 2 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • HOW CAN I RETRIEVE TH WATER TABLE IN PLAXIS-3D OUTPUT

    EMRE DUMLU
    EMRE DUMLU
    Hello , I am trying to inspect the water table coordinates in where pass through an embankment in PLAXIS-3D OUTPUT. Does anyone who know how can i get the coordinates ?.Thank you
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Forum
  • Water level values and symbols not showing up, or showing up in the wrong place in soil probe logs.

    Michael Davis
    Michael Davis
    I tried the fix described in this post from March, 2014, which describes an almost identical issue, but it did not fix it. Anyone else run into this and have other ideas? I'm at a bit of a loss. Thank you!
    • over 3 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • SIG Virtual Workshop: OpenFlows - Creating District Metered Areas to Better Manage Water Systems

    Kelly Fox
    Kelly Fox
    Title: SIG Virtual Workshop: OpenFlows - Creating District Metered Areas to Better Manage Water Systems Date/Time: June 18, 2020 11:00 A.M. EDT Presenter: Tom Walski, Bentley Fellow, Bentley Systems, Inc. Register Now This OpenFlows Special…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Add option to enter Specific Gravity of contents referenced to Air instead of Water

    Mike Dattilio
    Mike Dattilio
    The Specific Gravity based on water is not applicable to flow services that are 100% gas. Specific gravity for liquid is weight of liquid with respect to water and specific gravity of gas is weight of gas with respect to air. These 2 fluids are totally…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Ideas
  • Westergaard's added mass for hydrodynamic pressures: a simple case

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D CONNECT Edition V20 Update 1 PLAXIS 3D CONNECT Edition V20 Update 1 Date created 7 January 2020 Date modified 7 January 2020 The attached document describes the…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Waterlevel inspection and editing in PLAXIS 2D

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Version PLAXIS 2D 2015 Date created 09 July 2014 Date modified 09 July 2014 Since PLAXIS 2D AE, (user-defined) water levels are created as a series of water level segments. However, this makes…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • External water pressures on structures above the soil incorrect in 2D CONNECT Edition V20 [Solved]

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status Solved First Affected Version PLAXIS 2D CONNECT Edition V20.00.00 Found in Version PLAXIS 2D CONNECT Edition V20.00.00 Fixed and Released in Version PLAXIS 2D CONNECT Edition V20.01…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Custom level water condition might be reset after loading

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D 2015.00 Found in Version PLAXIS 2D 2015.00 Fixed and Released in Version PLAXIS 2D 2016.00 Issue # 24031 Date created …
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • Interpolate pore pressures with an inclined top cluster boundary does not work correctly in 2DAE.00

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D AE.00 Found in Version PLAXIS 2D AE.00 Fixed and Released in Version PLAXIS 2D AE.01 Issue # 20836 Date created 26 February…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
>