• Reference top view items not locatable

    Andrew Kenealy
    Andrew Kenealy
    Hi, I'm using CONNECT Update 14 - Version 10.14.02.01 When working with reference files a reference file rotated to show the top of the model I find that the items in the reference are no longer locatable and cannot be snapped to. In all other views…
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
  • [V8i] Global Display/Freeze in reference file

    Dominic Marriott
    Dominic Marriott
    Hi guys, I have a File A referenced into multiple files. I have turned on all File A's levels within View Display/Global Display/Global Freeze in the master File A The multiple files all have Global Display/Global Freeze off with no permission to…
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
  • To connect raceways in reference files and auto-route cables.

    Lalitesh Vaidyar
    Lalitesh Vaidyar
    Product(s): Bentley Raceway & Cable Management Version(s): 10.09.00.74 onwards Environment: N/A Area: Cable Routing Subarea: Raceway design Problem Description Cable cannot be automatically…
    • over 2 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • ORD changes not saved in original file after activating and deactivating a reference

    Andrea Gordon
    Andrea Gordon
    In OpenRoads Designer (Version 10.09.00), when I am working in a dgn (File1) for some time and make changes, then activate a reference (File2) for example to move a text element, then deactivate File2 and resume editing in File1, any edits that I made…
    • Answered
    • over 2 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • Extracting Tag Information from References

    Trevor Sedlock
    Trevor Sedlock
    Hello All - I am a fairly new MicroStation CAD admin and need some guidance for an ask I've been given. Is there a way to extract tag information from tags belonging to a reference in a file? For example, I have DGN A that contains a reference to…
    • Answered
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
  • can i add Grids and Graticules in Sheet files using the reference files coordinates?

    Brandy Lockhart
    Brandy Lockhart
    Does anyone know how, or if, I could add grids or graticules to a sheet file that references a map/model and have the grid show the referenced files UTM coordinates? I want to create an image within a sheet template that shows my model in a framed with…
    • over 2 years ago
    • OpenCities Map
    • OpenCities Map Forum
  • Hatching the referenced file elements

    Aadarsh Tale
    Aadarsh Tale
    I want to hatch the reference/non Bentley Raceway and Cable Management elements while using the 2D extraction, since BRCM only hatches the raceways and equipment and also extracts only the BRCM elements. So, I wanted to know, if there is a…
    • Answered
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • Default settings for drawing boundary and visible edge

    Brian MacCartney
    Brian MacCartney
    I would like to set my Drawing Boundary in the reference dialog box to always default to NONE and by Visible Edges default to DYNAMIC. Right now they set to NEW and CACHE by default. I would like to change those defaults to NONE and DYNAMIC. Thanks…
    • Answered
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • Dimension extension line style type not displaying

    Lonnie Robin
    Lonnie Robin
    I'm new to microstation, bare with me. I'm working in connect edition. I have a sheet model that I'm dimension a model I referenced in. I'm trying to place dimensions where the extension lines are center lines. I opened the dimension style, under symbology…
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • Reference Snapping

    Martin Brimble
    Martin Brimble
    I have been having problems with snapping to elements coming through from reference, it will work then suddenly for reason stop allowing snap. Not sure if its related but I also can be navigating within a 3D environment or just zooming in or out and…
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • How To Show Continuation with Reference File in OpenPlant Isometrics Manager

    Harshavardhan Kaduru
    Harshavardhan Kaduru
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): Connect Edition Environment: Windows 10 (64-bit) Area: Placement and Settings Subarea: Original Author: Harshavardhan K,Bentley Product…
    • over 3 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Toggle between / Swap saved views from reference

    Martin Brimble
    Martin Brimble
    Good Afternoon Everyone, I have multiple files with the same file referenced into the sheet, "reference contains 200 saved views" Id like to know how to swap the saved for another without having to reference all over again, this must surely exist…
    • Answered
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • Is there a way to prevent Microstation ss10 from loading a reference file when it is not active

    Chris Pfeil
    Chris Pfeil
    We are like many and working form home. With limited bandwidth between the office and our home based workstations there have been quite a few challenges. One of them is dealing with projects that have quite a few references (both dgn and dwg). We noticed…
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • How To Use Page Connectors to Show Information Between Two DGNs

    Harshavardhan Kaduru
    Harshavardhan Kaduru
    Applies To Product(s): OpenPlant PID V8i Version(s): Select Series 10 Environment: Windows 8.1/10 (64-bit) Area: Page Connectors Subarea: Customization Original Author: Harshavardhan K,Bentley Product…
    • over 3 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • To Copy Reference Elements of v8i Version in OpenPlant Modeler CE

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler CONNECT Edition Version(s): 10.05.00.27 Update 5 & Higher Environment: Windows 7/8.1/10 (64-bit) Area: Import- Export Subarea: Reference Original Author: Rahul…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Activate Reference - why is it missing in OpenPlant?

    Florian S.
    Florian S.
    Hello there, I am missing the option to activate a reference file. In MicroStation you can activate a reference file, the rest is greyed out, then you can make changes inside the reference file and afterwards go back to the normal file by clicking…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • Wrong coordinates when attaching references

    Björn Ohlsson
    Björn Ohlsson
    When I add certain references(dwg files that has correct coordinates when checking in AutoCAD) in Microstation to a .dgn file, they end up with completely off coordinates (however they still have the correct alignment). I´ve understood that it could be…
    • Answered
    • over 4 years ago
    • MicroStation
    • MicroStation Forum
  • Sheets don't reflect changes to intermediate or master files. - Levels on/off not updating.

    Michael Smith
    Michael Smith
    I have seen similar questions but the answers all seem to be ridiculous workarounds. It seems like the solution should be simple and straight forward and that makes me think that we are all missing something. For my project, I set up several “master…
    • Answered
    • over 4 years ago
    • MicroStation
    • MicroStation Forum
  • How to Set Default Value of Nested Depth in OpenPlant Modeler

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley…
    • over 5 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Is it possible to toggle the reference file drawing link symbol? MicroStation Connect?

    Mark Hird-Rutter
    Mark Hird-Rutter
    When I attach a reference file in MicroStation Connect I get a Drawing Link, a circle with line showing some information about the attachment. How do I toggle this off? I have found I can attache the reference file on a level and then turn off the level…
    • over 5 years ago
    • MicroStation
    • MicroStation Forum
  • To Fix Project Title Block Issue for Support Drawings

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Support Engineering Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Seed File Subarea: Display Original Author: Rahul Kumar, Bentley Product…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • SIG Virtual Workshop: MicroStation CONNECT Edition – October 10, 2017 - You're Invited!

    Patsy Gant
    Patsy Gant
    Mark your calendar for Tuesday, October 10, 2017 at 11 a.m. EDT or 7 p.m. EDT and attend the next MicroStation CONNECT Edition Special Interest Group (SIG) virtual workshop, General Drafting Techniques . Register today ! Sessions share the same agenda…
    • over 6 years ago
    • MicroStation
    • MicroStation Announcements Forum
  • SIG Virtual Workshop on April 25: MicroStation V8i − Reference Methods and Querying the Business Data

    Patsy Gant
    Patsy Gant
    Mark your calendar for Tuesday, April 25 at 11 a.m. EDT or 7 p.m. EDT , and join Bentley's Shawn McGaffick and industry colleagues for the next MicroStation V8i Special Interest Group (SIG) virtual workshop, Reference Methods and Querying the Business…
    • over 6 years ago
    • MicroStation
    • MicroStation Announcements Forum
  • Importing Models into ProjectWise Loses Reference File Path

    Harpreet Singh
    Harpreet Singh
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: ProjectWise Subarea: Original Author: Harpreet…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Several Models in one file

    ADRIAN COLDRIDGE
    ADRIAN COLDRIDGE
    Hello. I have several dgn files with two (or more) 3d models. Model A (default) and Model B, each model is referenced into a site layout dgn several times. If I close the site.dgn and reopen it all is fine. If, in the ref dialog box, I turn off…
    • over 8 years ago
    • MicroStation
    • MicroStation Forum
<>