• Modeling devices and components that are not explicitly available as an element

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, CONNECT Edition Area: Modeling Original Author: Mark Pachlhofer, Bentley…
    • 10 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • SIG Virtual Workshop on May 17: Bentley Hydraulics & Hydrology – Stormwater and LIDs

    Patsy Gant
    Patsy Gant
    Join Martin Pflanz for the next Bentley Hydraulics & Hydrology Special Interest Group (SIG) virtual workshop on Wednesday, May 17, 2017 at 9 a.m. EDT or 7 p.m. EDT . Guest speaker Jennifer Smith, a project engineer with Hayden Consultants, Inc. in Dallas…
    • over 6 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • What is the purpose the Rainfall File, Runoff File, and RDII File in the Calculations Options?

    Larry Abla
    Larry Abla
    Applies To Product(s): CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i (SELECTseries 2) or later Area: Modeling Problem What is the purpose the Rainfall File, Runoff File, and RDII File in the Calculations Options…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to create a Selection Set

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem How to create a selection set? Solution - Manual Creation Use the steps…
    • 8 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Sanitary loads are not being applied

    Jesse Dringoli
    Jesse Dringoli
    Product(s): SewerGEMS, SewerCAD Version(s): N\A Environment: N\A Area: Modeling Problem After computing a model that contains manholes with sanitary loads, the result field "Flow (System Sanitary)" reports…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Morphing conduits into pressure pipes

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): SewerCAD, SewerGEMS, CivilStorm, StormCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem Is it possible to change or morph a conduit into a pressure pipe or vice versa? Solution There are ways to…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Compacting data causes element display issues

    Scott Kampa
    Scott Kampa
    Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Changing symbol size, text height, or line width for elements in a model

    Luca Santos Billis
    Luca Santos Billis
    Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support…
    • 22 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Multiple CN numbers for a catchment and multiple catchments with a single outlet node

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): CivilStorm, SewerGEMS, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Is it possible to…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to model a swale in the storm and sanitary products

    Jesse Dringoli
    Jesse Dringoli
    Product(s): StormCAD, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem What is the best way to model a swale in the storm and sanitary products? Solution Assuming the swale is similar…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User Notification: Cross section maximum elevation is above the maximum headwater elevation

    Scott Kampa
    Scott Kampa
    Applies To Product(s): CivilStorm, SewerGEMS, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Description When…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Error message generated when loading background file

    Larry Abla
    Larry Abla
    Product(s): CivilStorm, SewerGEMS, SewerCAD, StormCAD Version(s): 08.11.xx.xx Area: Modeling Problem Description When trying the load a shapefile as a background file, the following error message is generated: "Object reference…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
<