• RAM Concept Load Run Down

    Jeff Chia
    Jeff Chia
    Hi, I'm using RAM Concept to do a load run down. I'm trying to use a live load reduction factor in my calculation. This is what I've done below accordance to FAQ but the results reaction still doesn't provide any live load reduction to me. I've…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAMDataAccess retrieve all column gravity forces like in RAMSteelColumn

    Zonglin Li
    Zonglin Li
    Hi RAM Support, I am working on a project and we are thinking about using RAMDataAccess to retrieve all gravity and lateral column gravity forces for foundation design. We would like the force to be retrieved like "Load Summary" in RAMSteelColumn module…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Why does Ram SS take 20 min to design the beams of my building?

    sam burke
    sam burke
    Like it says above, design of beams takes at least 20 minutes every time. But if i jump onto another computer and run the same model, it takes 8 seconds. I'm running a AMD Radeon RX 5700 XT. I've updated my drivers, and changed monitors to no avail. Does…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Frame Response Spectra Eccentricity & Rotate Axes

    Chris W
    Chris W
    G'day, If you define a Response Spectra (Custom or Code) with a rotated axes do the eccentricities get similarly translated, perhaps rotated about the COM? I seeking to confirm that I am offsetting the mass by 0.1b perpendicular to the direction of…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM SS v17.03 Release Notes

    Allen Adams
    Allen Adams
    RAM Structural System CONNECT Edition Version 17.03 SES Release Notes Release Date: January 27, 2022 This document contains important information regarding changes to the RAM Structural System. It is important that all users are aware of these changes…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • adjust concept geometry linked to structural system

    Erik Nelson
    Erik Nelson
    I am designing a PT parking garage that starts in structural system and uses concept to design the floor plates. I have ramps created as intermediate levels that make the column lengths in concept too short which affects the stiffness and hyperstatic…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Smart client crashes on long query due to obsolete ODBC driver and limited RAM

    Joseph Marin
    Joseph Marin
    Product(s): APM Implementation and Performance Management Version(s): 7 Environment: N/A Area: N/A Subarea: N/A Problem Description User found when opening APM to the default Asset view, that…
    • over 2 years ago
    • Asset Reliability | AssetWise APM
    • Asset Reliability | AssetWise APM Wiki
  • RAM Concept Vibration Analysis Eigenvalue Error

    Cristopher Montalvo
    Cristopher Montalvo
    I am analyzing a floor using RAM Concept and I tried adding point spring supports under beams... However, when I try to run the vibration analysis, I get an error saying "An error has occurred while solving the Eigenvalue problem"
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Incorporating the penalty on code based response spectra per ASCE7-16 if the structural period is greater than Ts

    Masood Inamdar
    Masood Inamdar
    Hi Guys, My building period is greater than the Ts value and per ASCE7-16, 11.4.8 the code based response spectra has to be adjusted (penalized). RAM does not adjust the spectra? is there a way we can incorporate it. I am running preliminary analysis…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Concept Strip Moment Discrepancies

    Max Karr
    Max Karr
    I have a flat plate, PT building that we have designed using concept and has already been constructed. Now the owner wants to change the residential penthouse to a nightclub which of course the floor is not designed for. I need to pull out design values…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Dowels

    Ben Ume
    Ben Ume
    I have a slab connected by dowels. What properties in the dowel mimicking slab element do i need to reduce to 0.001 to mimic DSDQ dowels please. I have modelled 50mm x 50mm x 50mm dowels in concrete and need to change kFs/kFr/kMrs etc
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM connection- CHS Column & I beam Weld connection

    K JISHNULAL
    K JISHNULAL
    Hi, I am new to RAM Connection and wanted to do the moment connection in CHS sections in one of my project. Can I know whether the connection is available now? If so, which version should I install for the same? ( Circular Hollow Section column and…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • ASCE 7, AISC 360, and the Effective Length Method in the RAM Structural System

    Allen Adams
    Allen Adams
    Note: This is a companion to the article, ASCE 7, AISC 360, and the Direct Analysis Method in the RAM Structural System . 27 June 2023: Corrections made in Step 4 for structures in Seismic Design Category B and Seismic Design Category D, and clarification…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • ASCE 7, AISC 360, and the Direct Analysis Method in the RAM Structural System

    Allen Adams
    Allen Adams
    Note: This is an updated and expanded wiki based on the requirements of ASCE 7-16 and AISC 360-16. The wiki previously was based on older versions of those documents. 18 July 2022: Corrections made in Step 4 for structures in Seismic Design Category…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Not a valid "Column base (CB)" joint

    Dan Calabro
    Dan Calabro
    I am attempting to assign and design gusset plate connections using Ram connection using data from a RSS model. When trying to assign a connection detail to a joint the error The joint composed by node "171" and members "120, 886" is not valid "Column…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Structural Worksuite

    Carlos Aguera
    Carlos Aguera
    Are you working on concrete structures and want to see how you could be more efficient with your analytical tools? Here is a great blog and webinar series for structural engineers focused on reinforced and post-tensioned concrete design is now available…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Announcements Forum
  • RAM Structural System - Load Distribution on Lateral Walls

    Gerald Evan
    Gerald Evan
    In RAM SS, how does the program distributes the lateral load (seismic and wind) in a rigid and non-rigid diaphragm? What are the differences in outcome with the different diaphragm types specified? My problem: In the picture below, I am showing a…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Controlling Fundamental Building Period

    John Gervais
    John Gervais
    I am running the seismic analysis for a 3 story structure and have questions about how to determine the appropriate building period to use for the seismic analysis. Gravity system is typical steel frame, with composite slab/framing at 2nd and 3rd Floors…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Small perimeter reinforcement - "What is it good for?" asks Edwin Starr

    Sam Leimer
    Sam Leimer
    I'm modeling a very simple 10" roof slab with some long-ish cantilevers (22" from edge of slab to face of wall). For some reason, the Concept module of my RSS model insists on putting 6" or 12" anchored rebar around most of the slab's perimeter, top…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Is there a way to customize this connection in RAM so the braces and beam all bolt to a common plate?

    James Pittman
    James Pittman
    See the attached image. I am wondering if there is a way I can use one large plate to connect all of the braces and the beam to the column, using bolts into the large gusset that is shop welded to the column. Can I replicate this in RAM? if so, how? Thanks…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Moment Not Transferred To Beam Ends Correctly

    Peter Ranieri II
    Peter Ranieri II
    Hello, The moment in my frame does not seem to be correctly transferring to the fixed ends of the steel beams. All of the moment connections are set to a fixity of "XXX" and are lateral members. The ends do have moment values but seem to be way smaller…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Concept, RAM SS, and RAM Elements - ACI 318-19

    Sean Smith
    Sean Smith
    Are there plans to include ACI 318-19 provisions in any upcoming releases for the RAM programs? If so, is there an ETA on this? Our AHJ will be adopting IBC 2021 in a few months, but we need to have the ability to start designing concrete structures in…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Concept - Add "Help" button to dialog boxes similar to RAM SS

    Sean Smith
    Sean Smith
    As the title implies, it would be helpful if dialog boxes within RAM Concept had a "Help" button that takes you to the section of the help file describing the various settings in the dialog box. This feature is already present in RAM SS, and it would…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM Concept
  • RAM SBeam latest version?

    Pascual Mauricio
    Pascual Mauricio
    Hello all, I am looking for the latest version of RAM SBeam. Is it RAM SBeam v 7.0? Also, if anyone can include a link for the download, thank you. By the way, I wasn't sure if this forum is the proper location to post this question for SBeam. Moderators…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Concept Rebar out of section

    Eduardo Molina
    Eduardo Molina
    Hi, I'm working on a mild reinforced slab and it seems to be working fine, however im getting a warning that says some of my rebar is out of seciton. I already checked and the user defined rebar is within the trimmed section, i looked at the Cross Sections…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
<>