• Interpreting overflow results when using manhole or catch basin Surface Storage
    Scott Kampa
    Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i (08.11.05.58+) Area: Calculations Problem How do I interpret the results when using the surface storage...
  • HGL after side weir & Modeling pumps
    Mike B.
    Hello, I have a complicated system described as follows: Upstream storage pipes that gathers onsite drainage, drains to an 6" pipe that represents a proprietary treatment system. Excess flow drains...
  • Creating catchments and assigning nearest manholes as outflow element.
    Asmita Dahal
    Hello, I have a question regarding catchment delineation and how to apply automatic catchment delineation to my model. I imported the manholes and conduits into my model via model builder and now I want...
  • SewerCAD/GEMS: Set Manhole Elevations to be Equal to Invert Out
    Robert Tejano
    SewerCAD/GEMS: I currently have all my manhole invert elevations set to zero, but I do have invert elevations for all the conduits. Is it possible to set all the manhole invert elevations to be equal to...
  • How do you model an elliptical culvert within the composite outlet structure tool?
    Elizabeth Calt
    I have PondPack Connect edition. I'm trying to model and elliptical culvert in the composite outlet structures editor, but the only culvert shape options are circular or box and the charts/nomographs only...