• Compression only spring showing tension
    Arvind Marathe
    I have gone through all the forum to find the answer. I see some answers for Foundation / Plastic mat type but nothing for single supports. I am running SPMT analysis for the modules and respesenting each...
  • WARNING IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION
    Abhisek M
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: STAAD.Pro Analysis Solutions Subarea: Seismic Analysis...
  • Zero tension analysis
    Abdi Musa
    Hey, I am checking the minimum bearing pressure for the mat slab. I have 500 iterations to run. Still, I see negative minimum pressure. Why I am not getting zero tension at the base of my mat? Thanks...
  • RAM Concept Licensing and Usage of Post Tension (PT) Features
    Karl G
    ***Note - The RAM Concept Post Tension License was consolidated into the base RAM Concept License in April 2023. The information and recommendations on this page no longer apply. Please visit this page...
  • P-delta analysis with tension only members in physical modeler.
    Ze'ev Kouznetsov
    Hello, I am using STAAD PRO connect edition V22 physical modeler update 12. In the model used braces as TENSION only members. I also perform P-delta analysis and define number of iterations 16. However...