• RAM Concept - Two Way slab - Shear - ACI 318-19
    Farzaneh Raji
    Hi, I'm checking the shear for a two-way slab using RAM Concept and ACI318-19. I've added punching shear checks, so the program will design the stud rail if needed. When I check the results for punching...
  • RAM Analysis and Stability Design for ACI Concrete Shear Walls
    Brian S
    I found this great video that provides some info on ACI stability checks for concrete columns (and I assume its true for concrete shear walls). Is there a written version of this, similar to how you provide...
  • RAM Structural Concrete Column ACI 10.3.1.2
    Michael Zaitz
    All, Does the RAM Concrete Module check for ACI 318-14 10.3.1.2 for column design and checks? I could not find anything on the wiki regarding this. Thanks, Mike
  • Concrete Floor System Using Pan and Joist System Shear Failure at Column Intersection
    Luis Hasbun
    I am modeling an existing 1960's floor pan and joist system in RAM concept to determine what maximum storage live loads can be used in this floor. Everything checks out except for one way shear checks...
  • Design of different moment resisting frame as per ACI code
    Abhisek M
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): All Environment: N/A Area: Concrete Design Subarea: Column &...