Hi Benjamin,
I don't think you can reposition existing cross section named boundary from one station to another. However, you can add a new named boundary to your specific station and have it contained within the same named boundary group. Just make…
Terrains cannot include two points with different elevations at the same x,y coordinates so where there are vertical lines in the template the terrain will skip one of the points. The workaround is to put a slight slope/offset between the points so that…
In case you missed it:
OpenSite/OpenRoads/OpenRail Designer 2021 R 2 (10.10.20.78) - OpenRoads | OpenSite Announcements Forum - OpenRoads | OpenSite - Bentley Communities
Hi Adam,
Must be soon - some videos below added to the Wiki recently:
White Space Management: Manage Modifications - OpenRoads | OpenSite Wiki - OpenRoads | OpenSite - Bentley Communities
What's New - OpenRoads | OpenSite Wiki - OpenRoads |…
Hi,
These links might help:
Conveying Asset Management with OpenRoads Designer Learning Path
Webinar: Creating Tables, Reports, and Extended Attribution with Item Types using OpenRoads Designer
Webinar : With OpenRoads Designer, an Ordinary…
Hi Max,
These should help:
Video: Item Type Syntax for Nodes and Conduits - OpenRoads | OpenSite Wiki - OpenRoads | OpenSite - Bentley Communities
OpenBridge Modeler 2021 Release 1 - Full list of Item Types - LARS | LEAP | OpenBridge | RM…
Hi all,
I have just seen the SUDA Change Tracking feature in ORD 2021 Release 1 which is something we urgently need in the main ORD toolset. We tried DGN Design History, but since the "Restore" option can't be turned off we cant use it (as it will…
Thats right, MX 3d strings (including M-strings) will import into the 3d model and Geometry (G-strings) will import into 2d.
Use the Plan by 3D Element tool to get 2d geometry from the 3d channel line and Simplify if it doesnt detect the 3d (if you…
Generally, first you need to design your ditch profile in the profile model and set feature definition (Linear/Profile).
The annotation for profiles in the drawing model has been controlled by the annotation group which in turn associated with the feature…
Victoria
Not sure about the CDOT workspace but I would suggest that the change in corridor feature definition has applied a different template drop interval multiplier in your corridor.
For example if your default template drop was 5m when you created…
How can we do ? it seems to me that this is a very useful action for understanding the plans. If I understand correctly, we have to switch to V8i and go back to connect? It is not very easy for me, an earthmoving software without this function ???
…
Hi Adam,
Not sure if it does much more than the Explorer one, but does the new "geometry processallobjects" keyin do anything better?
We're still using our custom "Synchronise all Templates" macro to sync all Template Drops/Linear Templates unfortunately…