• RE: Keep getting a run time 53 error after trying to set up a dxf in Netsys.

    Krishnendu Paul
    Krishnendu Paul
    Hi Alex, Did you check whther you followed the proper installation procedure shown here ? Major issues such as Run time error 53 points that the installation has not gone well. Regards, Krishnendu
    • over 1 year ago
    • Hevacomp
    • Hevacomp Forum
  • 2021 PartL Compliance Changes

    Steve Cocchi
    Steve Cocchi
    Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Part L Overview With the introduction of the 2021 PartL building regulations much more stringent building compliance requirements will be…
    • 2 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Split level roof & inserting windows into wall / partition

    Graham Barber
    Graham Barber
    I have a split level roof with a vertical section exposed to external (wall) but below it's a partition - in Hevacomp you could use vertical infil and insert rooflights for windows - my question is how do you do that in Openbuildings ? I've seen Shane…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • Energy Simulation Forum
  • RE: Virtual walls

    Shane Regan
    Shane Regan
    Hi Tony, Virtual walls will enable you to do what you describe, just it is for dynamic simulations rather than the steady state calcs. EG: The below from the manual may also be of interest: Regards, Shane
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • Energy Simulation Forum
  • RE: Deleted windows still showing in the 3d view

    Dan Rotari
    Dan Rotari
    Thank you for the suggestion about the plenums, I use them often. My actual version is: Link to the workspace: https://drive.google.com/drive/folders/1vhK9kdPpXQCRth7dW20fOIho9onTCpR-?usp=sharing Regards
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • Energy Simulation Forum
  • Context Menu Blanking Out

    Krishnendu Paul
    Krishnendu Paul
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Problem While working on a model, sometimes the context menu (the menu that arrives after the right-click) does not appear, and users might have to exit the software…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
    • Eduardo Cortes
  • RE: context meu blanking out

    Krishnendu Paul
    Krishnendu Paul
    Hey Keith, I hope this is resolved now, please folow the article here for the detailed solution. Regards, Krishnendu
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Trace room not working due to Active Floor

    Steve Cocchi
    Steve Cocchi
    Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Building Modelling Overview Care must be taken when tracing rooms on multistoried projects; i.e. when tracing rooms above/below other rooms…
    • 8 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • RE: OBD 9 Compound Slab Worries

    Krishnendu Paul
    Krishnendu Paul
    Hello Duncan, Thanks for raising this! Could I please know what is the workflow you are following, cause to put a punch hole in your slab you woud have to select a cutting geometry of the desired shape first, and then select the slab you want to punch…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • RE: OpenBuildings Pipe/Duct Sizing

    Krishnendu Paul
    Krishnendu Paul
    Hi Jon, Thanks for reaching out! yes, it would not be possible to buy Hevacomp alone. We have OpenBuildings Energy Simulator (a replacement of Hevacomp). Energy Simulator has almost similar funtionalities as Hevacomp and we are continuously developing…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • Energy Simulation Forum
  • RE: Installation files for Hevacomp

    Patrick Doyle
    Patrick Doyle
    Thanks Krishnendu. Got the files now. Could you also explain how we can upgrade it now. Should we remove the old version first?? Also please advise if we need a new activation key etc.
    • over 1 year ago
    • Hevacomp
    • Hevacomp Forum
  • Importing custom Weather Data files

    Shane Regan
    Shane Regan
    Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Data Managers Subarea: N/A Overview OpenBuildings Energy Simulator allows all formats of weather…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
    • Adrian Holmes