• RE: OpenPlant Isometric Manager Administration

    Tuan Le
    Tuan Le
    Thanks heaps, Harpreet. That's good news indeed and I will soldier on with my investigation then.
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: How can I open Descartes SS6 in Openplant SS6?

    Tony D
    Tony D
    Hello Erick, First things first - make sure you installed Bentley Descartes for MicroStation V8i (SELECTseries 6) build 08.11.09.720. This is the layered Descartes for use inside of MicroStation and OpenPlant Modeler. Once this is installed, you need…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • OpenPlant Product Compatibility

    Rahul Kumar
    Rahul Kumar
    Here compatibility across different release versions of OpenPlant Product with Operating Systems, ProjectWise and various Database types is presented. The compatibility matrixes are available in pdf format thus could be downloaded. Follow the link below…
    • 9 months ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
    • Aishwarya Kulkarni
    • Ashutosh Patil
    • Vikrant Kale
    • Farooq Riaz
    • Abhilash Panchal
  • RE: OPPPID Drawing Revision

    Bhadresh Nanavati
    Bhadresh Nanavati
    Thanks very much for your help. I wish you had answered this before as I was told that it is a defect issue by the other support person.
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: OPPPID Drawing Revision

    Bhadresh Nanavati
    Bhadresh Nanavati
    Thanks for your help. It did work. You have the best support knowledge.
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: OPPPID Drawing Revision

    Tony D
    Tony D
    Hello Bhadresh, In order for the PID_DOCUMENT class to support REVISION property with alpha characters you will need to do the following. Launch Class Editor. Load the OpenPlant schema located here (by default in Windows 7) "C:\ProgramData\Bentley…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
    • Bhadresh Nanavati
  • RE: Where i find the different gauges in OpenPlant Modeler

    Markus Wilbers
    Markus Wilbers
    Yeah, thats helps me ;D sry i had say this more clear i dont want different graphics in OPM i want difference symbols on the isometric, and with the solution from Kumar i had difference classes with difference symbols in the isometric. Thanks all…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: Pressure Relief Valves with different inlet / outlet pressures OPM v440

    Grant Wheatley
    Grant Wheatley
    Thank you Harpreet all working, I was heading down this process but wiki clarified the final part.
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: How to prepare a catalog of Basket and T-Strainers ?

    Kestutis Mitkus
    Kestutis Mitkus
    Hello Przemysław Chmura, Exact information about fields contained in factory-shipped Bentley catalogs and specifications can be found in C:\Program Files (x86)\Bentley\OpenPlantModeler V8i\Documentation\OPSpecGen.chm Help file. Open this file and go…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: Questions about OpenPlant PID

    Tony D
    Tony D
    Hello and thank you for your inquiry. It would be helpful if you could identify yourself. In response to your questions see below. 1. OpenPlant PID does store Control/Input for related instruments. This is currently not stored in the database. …
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
    • REI
  • To Modify Pipeline Tag Name in OpenPlant Modeler

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Properties Subarea: - Original Author: Rahul Kumar, Bentley Product…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
    • Giuseppe Gaudiomonte
    • Rajesh Agrawal
  • To Modify Default Outside Diameter Value for End Types in OpenPlant Modeler

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: - Original Author: Rahul…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
    • Vivek Baraiya
    • Rajesh Agrawal
  • How to Populate Gridlines Reference Dimensions Automatically

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 & 08.11.09.564 Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original…
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
    • Rajesh Agrawal
  • RE: How to disable prompt while applying Batch process of Autoplant P&ID to OPPID conversion.

    Tony D
    Tony D
    Krishna, This is due to an incorrect property mapping in the AutoPLANT_PID_Conversion schema. To resolve this you will need to determine which page connector class is being used in your AutoPLANT PID drawings. An example of this would be "tofrom2…
    • over 8 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • How to Use Grid Lines in OpenPlant Isometrics Manager

    Abhijit Bute
    Abhijit Bute
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki