• RE: User Defined Attributes are not updating

    Jesse Dringoli
    Jesse Dringoli
    If you are opening the flextables from the View Ribbon menu, those are referred to as the Predefined Flextables, which are used by all models on your computer as Yashodhan mentioned. If you are adding User Data Extensions to a specific model, you may…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: ISO-9001 Audit for WaterGEMS

    Sushma Choure
    Sushma Choure
    Hello Chetan, Below link will give you access to validation certificate for WaterGEMS and other OpenFlows products, which you can provide to the audit team. They show that the software's hydraulic results match published or known results. Validation…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: User Defined Attributes are not updating

    Yashodhan Joshi
    Yashodhan Joshi
    Hello Chetan, The flextable stores the information you had for the earlier project and that is why you might be seeing those fields when you initially open the flextable. As you go to Edit these are updated and you wouldn't see them. Is this what is…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: What data Flow should be chosen for Calibration

    Tom Walski
    Tom Walski
    If you have flow data for each DMA, this will enable you to determine the average demand and develop different demand patterns for each DMA for each day you want. I'd suggest using more than one day to check how similar each day is. When I would make…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: What data Flow should be chosen for Calibration

    Joeri Legierse
    Joeri Legierse
    We usually take a day with a high peak flow, as deviations in pressure caused by incorrect pipe-roughnesses or incorrect isolation valve settings tends to be highest on such days. Make sure the day you pick has a high peak flow because of consumption…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: How to use Query Builder for filtering multiple zones

    Jesse Dringoli
    Jesse Dringoli
    To add to Sushma's reply - another option is to use the "IN" operator - HMIActiveTopologyIsActive = True AND Physical_Zone IN (21487,22736,74296, ...) See related wiki article: Using the IN operator to query for elements in a set list of criteria
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: How to set up a demand pattern when flow of once in "x" days is required?

    Sushma Choure
    Sushma Choure
    Hello Chetan, The key element while setting yo daily pattern and hourly pattern is setting up correct start time and correct simulation start date in the calculation options. The reason why you see different pattern followed than what mentioned is…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: Residual Head at Inlet of Tank (Filling from Top)

    Jesse Dringoli
    Jesse Dringoli
    If you are using the top-filling tank feature in WaterGEMS and you have "inlet valve throttles" set to "true", then the tank will only fill if the hydraulic grade is above the inlet pipe invert ("level (inlet invert)" plus the "elevation (base)") plus…
    • over 4 years ago