• RE: how can i hide some pipes from velocity or pressure view ?

    Jesse Dringoli
    Jesse Dringoli
    If you only need to make them disappear temporarily, you could simply delete them, take a screenshot, then undo the deletion. The color coding method requires you to color code a certain field. Perhaps you could add a User Data Extension for example…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: Easy way to get to Graphs from a Selection Set?

    Rob Gurrieri
    Rob Gurrieri
    Hi Gary, Network Navigator and Quick Graph may be a good option for you. On the Ribbon, navigate to the View tab, click "Quick Graph" and then click "Navigator" to open those windows. In the Network Navigator window, use the combobox at the top…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: Pattern usage questions.

    Yashodhan Joshi
    Yashodhan Joshi
    Hello Gary, The patterns that you specify at the Customer Meters or Junctions (if you are not considering Customer Meters) are generally the Diurnal curves which are the usually the 24 hours consumption patterns for a node or customer meter. If you…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • RE: Pattern usage questions.

    Joeri Legierse
    Joeri Legierse
    I've struggled with this in the past and the most intuitive approach (in my opinion) that we applied was this: Base Demand (customer meter/junction): Demand based on the latest billing data (in m3/h, so for example yearly demand/(365/24)). This value…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How does the Automated Fire Flow analysis work?

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli & Mark Pachlhofer, Bentley Technical Support Group Problem How does the Automated Fire…
    • 10 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
    • Kenneth Cannady-Shultz
  • RE: "Graph Series Options" Default Check Boxes

    Mal Sharkey
    Mal Sharkey
    Have you tried saving the graph(s) you are interested in so that you can reopen them later? Regards, Mal
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum