you are using 2 Applicaton Windows
by enabled "Open Two Application Windows" in Workspace Preferences
you can move the windows or uncheck the option.
See for example
http://communities.bentley.com/products/microstation/f/273/p/105573/317981#3…
Hi Junying Chen,
This problem was sent to the developers and they found that there is a problem with a file in the English and New Zealand localization. The other localizations appear to be fine. To fix the problem navigate to the following directory…
Hi Junying,
What operating system do you have on your computer? Also could you type PS_Version on the command line in ProStructures and send me a screen capture of that? The message you see seems to be for SS4 Prosteel but that does not seem right…
Hi Steve Crabtre!
Thanks for answer my question.
When I import the model into autocad appear this error . I do not know how to load the mapping file where, Can you just help me mapping file anywhere?
Thank you!
Hi Junying Chen,
What template are you using when you create a new project in ProSteel. Are you using the default AutoCAD or one of the template files setup to work with ProSteel. I had no problem importing your model. I did not need to map any shapes…
Hi everyone!
I'm studying about stadd pro v8i, it's very interesting and I'm curious about it.
I really want to see the the real project about stadd pro to see and study. If you guys have one please give me the files ! I'm very please if you do. …
You have activated the deflection diagram. On Ctrl+ Scroll up decreases the scale for deflection and that results is enlargement in the display of displacement.