• RE: How to change the PP units?

    Aparna M
    Aparna M
    So as far as I understand, you are wanting to change the tsf units in the report. This will be in the Component description table in the data design. See this screenshot.
    • over 1 year ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to change the PP units?

    William Ladd
    William Ladd
    Hi Pelelo, it depends where on the log you are still showing TSF as the units. If it is in the column header, you need to open the report entity, select the "Column" tab, and edit what is in the "Column Header Label" field. If it is associated with each…
    • over 1 year ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to add notes at the end of borings?

    szang
    szang
    This is covered on page 90 of the report tutorial. See the discussion in the following thread regarding alternative approaches that will deal with the situation when your end of boring notes are at the bottom of the page. (9) Moving end of hole notes…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to add elevation and Depth in the same column

    Allan P.
    Allan P.
    You need two columns but set their positions to the same number so they print on top of one another. You'll need to figure out if you want to keep the depth ticks or the elevation ticks and which column will have text and which wont.
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to disable the file path?

    Aparna M
    Aparna M
    Track codes are under Drawings>General Drawings, in the yellow selector look for Track_Codes
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to disable the file path?

    Judy Smith
    Judy Smith
    In report design, go to the report that you want to delete it from. For your fence, go to Fences and in the yellow dropdown menu at the top of the page, choose the fence you wish to delete it from. When the page opens, find the DWGLIB TRACK CODES ALL…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to disable the file path?

    Judy Smith
    Judy Smith
    If you only want to remove the path information for one project, you can manually remove in gINT's draw function. If you would like to remove it permanently, you can do so in Report Design by removing the DWGLIB TRACK CODES ALL block.
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to add an extra column in the logs

    szang
    szang
    I just re-looked at the tutorial. There is an entire section and detailed example on how to add a column to an existing log.
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to remove the "USer Report Variable" Window?

    szang
    szang
    User report variables are specified in the properties of the report page. Open the report in the report design tab and select File, page properties (F8 is a shortcut key for this). In the General tab of the page properties you will find the user report…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to add an extra column in the logs

    szang
    szang
    First I would advise you to do the log reports tutorial located here: (+) Logs Tutorial for Log Report Design - OpenGround | gINT | Keynetix Files - OpenGround | gINT | Keynetix - Bentley Communities This will get you familiar with how to better work…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to Remove Non N value expression in the boring logs.

    Phil Wade
    Phil Wade
    Without going into the specifics of the question, everyone should be aware of these functions, they will avoid situations like this <<ListBuildSepTrim(<separator>,<<expression 1>>,<<expression 2>>,...)>> <<DelimitData([leading delimiter],<<expression…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • How to add an extra column in the logs

    Pelelo
    Pelelo
    Hello, I would like to add an additional column in the boring logs, just for the SPT-N values. Refer to the file attached. Can anyone provide guidance?. Thanks. PDF
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to Remove Non N value expression in the boring logs.

    szang
    szang
    As I said my example was an example. You need to adapt it to your specific data fields and requirements. In this case the name of your blows field appears to be <<SAMPLE.Blows 1st>>; my example used <<sample.blows_1st>> which is not the same thing. Also…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: How to Remove Non N value expression in the boring logs.

    szang
    szang
    There are 2 ways to acomplish this, 1. modify your text expression in in the text vs depth entity to return nothing for samples that have no blow counts. a text expression such as: <<HasData(<<Sample.Blows_1st>>,_ [your current expression for assembling…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum
  • RE: End of Boring Label at bottom of borings

    Kirk Johnson
    Kirk Johnson
    You have modified the vertical offset to a positive 2 and have set the offset units to page which is likely the cause. This means it is probably offsetting the text 2 inches above where it should be on the page. Remove the offset or make it a small…
    • over 2 years ago
    • OpenGround | gINT | Keynetix
    • gINT Forum