• General reading error in RCDC, Input table or Frame Assignments-output stations

    Ranjana Shinde
    Ranjana Shinde
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: General Original Author: Ranjana, Bentley…
    • 10 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Custom section in database lost in update

    Saul Cuen
    Saul Cuen
    Recently I updated to Staad.Pro 22.04.00.40 just to find out that all my custom sections that I added into the Section Database are now missing. Naturally, compiling this information took a lot of time and now I have to look up again for the same sections…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Corrupt Ram Connection Files

    Seth Guthrie
    Seth Guthrie
    Applies To Product: RAM Connection First Affected Version: 13.00.00.56 Found in Version: 1 3.00.00.56 Fixed and Released in Version: 13.01.00.76 (13.00.00.59*) Environment: x64 Area…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • How can I access sections from older AISC section databases in the STAAD.Pro CONNECT Edition?

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): CONNECT Edition Environment: ALL Area: Modeling Solutions Subarea: Properties Original Author: Sye Chakraborty, Bentley…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Section Database in STAAD Connect Physical Model

    Vianney Rose Llopis
    Vianney Rose Llopis
    Is it possible to customize an existing section database to include only certain sections & rename it as a database for only a particular project? For example, a project that utilizes British sections will use only selected members due to commercial…
    • over 5 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Existing custom steel section databases cannot be opened in the STAAD.Pro CONNECT Edition

    Carlos Aguera
    Carlos Aguera
    Product: STAAD.pro First Affected Version: 21.00.02.30 Found in Version: 21.00.02.30 Fixed and Released in Version: 21.03.00.146 Area: Custom Steel Section Database Issue #: 870111 …
    • 7 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Issues with the AISC 14.1 Profile Database

    Sye
    Sye
    Applies To Product: STAAD.Pro First Affected Version: Found in Version: 20.07.11.33 Released in Version: 20.07.11.45 Environment: All Area: Modeling Subarea: AISC_14…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Unsupported Database Version Error RAM Concept Import

    Karl G
    Karl G
    Applies To Product: RAM Structural System; RAM Concept First Affected Version: 15.03.00.000 Found in Version: N/A Fixed in Version: N/A Environment: All Area: Import Subarea…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Newly added section shows up at the end

    Sye
    Sye
    Product(s): Limcon Version(s): V8i Environment: N/A Area: Section Library Original Author: Bentley Technical Support Group I am adding a new section to Limcon but the section shows up at the…
    • over 7 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • STAAD.Pro V8i SS6 - AISC 14.1 Profile Database

    Carlos Aguera
    Carlos Aguera
    It has been noted that the AISC 14.1 section profile database that is delivered with STAAD.Pro V8i SS6 (20.07.11.33) has a couple of issues which can be problem with the following profiles:- 1) Models that include standard or extra strong pipe sections…
    • AISC_14.1.zip
    • over 8 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Blog
  • RAM Connection V9.0 Release notes

    Carlos Perez
    Carlos Perez
    Enhancements ANSI/AISC 360-10 Specification for Structural Steel Buildings. ANSI/AISC 341-10 Seismic Provisions for Structural Steel Buildings ANSI/AISC 358-10 with ANSI/AISC 358s1-11 Prequalified Connections for Special and Intermediate Steel…
    • 29 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RAM Connection v9.0 User Databases

    Seth Guthrie
    Seth Guthrie
    Applies To Product(s): RAM Connection Version(s): 9.0.0 Environment: Windows 7; Windows Vista Area: Installation Subarea: Tables Problem Description After…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • View related content from anywhere
  • More
  • Cancel