• Knee brace gusset to beam/ column connection eccentricity due to workline not coinciding with weld centre

    Anurag E
    Anurag E
    We have encountered a problem while performing checks in vertical brace knee brace. The software does not allow us to enter the values of Xleft and Xright, which represent the eccentricity from connection centre to workline. As a result, the calculation…
    • 2 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Bolted Beam Splice Connection

    Mel Bolin
    Mel Bolin
    Below is an image of a bolted beam splice connection that I'm working on. RAM Connection considers the eccentricity of the bolt group to be 3.125in and the coefficient for eccentrically loaded bolt groups to be 8. I believe that the eccentricity…
    • 9 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Input & Reported Column Eccentricity

    Angelica Tijssen
    Angelica Tijssen
    How can I confirm column eccentricity in RAM SS? Within the Data Echo report it notes in the column table that "values with a + indicate eccentricity plus 1/2 column dimension", then in the table is notes "+100" however these notes in the report do not…
    • Answered
    • 11 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Connection in Staad - Bolt shear ratio in beam-girder single plate connections

    Agustin Rowell
    Agustin Rowell
    Hi Everyone! I am trying to verify a beam-girder single plate connection: I don´t understand why RAM Connection considers this: I understand that it calculates the bolt group capacity as the product of one boly shear capacity by the coeficient…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • STAAD Foundation Advance CE do not check excentric foundation

    EdwardVC
    EdwardVC
    STAAD Foundation Advanced CE do not check eccentric foundation I was tried to design a isolated foundation with a eccentricity and the program shown a warning message, that the function was unable to perform the design. Does exist any particular reazon…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • WT/Angle Section connection eccentricity

    Namit Sharma
    Namit Sharma
    Is there any way to simulate the eccentricity due to connection of angle/WT section with gusset in STAAD? Or do we need to perform additional check for member design due to this eccentricity manually?
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RE: Dynamic eccentricity for earthquake loading

    Sye
    Sye
    The analysis output file only reports the accidental eccentricity but the dynamic eccentricity (DEC ) is not reported which can be confusing. However the analysis does automatically consider the torsion from the dynamic eccentricity along with the accidental…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Concrete Column Minimum Eccentric Moment

    Seth Guthrie
    Seth Guthrie
    Product(s): RAM Structural System; Concrete Column Version(s): Any Area: Design Why is the reported moment larger than the reported member forces? The concrete column design report indicates the ultimate factored…
    • 7 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RAM Steel Columns [FAQ]

    Seth Guthrie
    Seth Guthrie
    Product(s): RAM Structural System; Ram Steel Column Version(s): Any Environment: N/A Area: Design Original Author: Bentley Technical Support Group Why don't the column design forces equal the…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Modelling eccentricity of columns with cantilever beams in RAM SS

    Landon Harman
    Landon Harman
    We have a situation where an existing building utilizes platform-framed construction and several columns have beams with 10'-0" cantilevers which run over top of them. We do not feel it's conservative to assume a perfect fulcrum (i.e. zero eccentricity…
    • over 9 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAMSS Concrete Beam Eccentricities

    Chris
    Chris
    Is there a "best practices" method for modeling concrete beams with eccentricities? Please see attached picture. All perimeter girders on this specific project (66" pan joists, typ) have a grid --> pan dimension held at 1'-6" creating a 2" eccentricity…
    • over 14 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • View related content from anywhere
  • More
  • Cancel