I have a location where two deck types meet, one with a roof loading and the other with a floor loading. There is an odd line load being applied in the analysis that is greatly affecting the design on my beams and columns. I cannot see to find the source…
Hi,
My company usually only use one wind definition for wins area load and factor it for different wind cases. I have 3 wind definitions, and I am getting these messages in Editor. Is it a warning message?
DEFINE WIND LOAD TYPE 1 NESC HEAVY INT…
Applies To
Product(s):
STAAD.Pro
Version(s):
ALL
Environment:
ALL
Area:
Modeling Solutions
Subarea:
Other
Original Author:
Sye Chakraborty, Bentley Technical Support…
This should be an easy one for you all.
When you place a load over a given area and then add an additional load that overlaps it, does STAAD consider the loads additive or choose one or the other? I'm thinking specifically if you define a live floor…
Seismic load combinations are:
1.2D + 1.0E + L + 0.2S
0.9D + 1.0E + 1.6H
While calculating the E loading, shall we do it for 1.0D + 1.0L OR based on the factors indicated in the mentioned combinations:
1.2D + 1.0L
0.9D
**It is known that…
Dear all,
I am a beginner in STAADPRO and I have already read some topics on this forum about this problem. And I tried to improve my model so on.
And I have a lot of warnings . Can anyone help me giving me some advices and tell me what's wrong with…
I am modelling a building that has a steel roof truss on the roof slab. Now while assigning dead and live load (Floor Load) on that particular floor, I am unable to see a proper distribution of forces that have occurred through the other floors. I am…
Lately I've been running into issues with my lateral analysis on a large, square steel framed building. The roof is an 1-1/2" metal deck that slopes in one direction and drops 10' over the length of the building, which I've modeled as a semirigid diaphragm…
If there are gravity walls or gravity columns (any material) on top of a gravity concrete beam will these display in these views/report?
Or is it only tributary loads (point and line loads) on that floor?
Thank!
Trying to apply nodal loads to a frame that is skewed and it seems the options are limited to X and Y only. Applying with X and Y components at frame end did not produce expected results.
Hi,
I am designing a steel beam grid (IPN240) and I want to apply a uniform surface load (10 kN / m2) to be taken by the beams.
Is there any way to do this without creating a slab on which to apply the uniform surface load?
As shown, no…
Hi, i have a problem when ytrying to use floor oneway loads,
I specify the range in x,y,z and i use the "towards" option, because i don´t want the program to use always the short direction:
ONEWAY LOAD YRANGE 2.16 2.18 ONE -0.25 XRANGE -14.51 -10…
I'm working in the RAM Elements Concrete Wall Module, and have applied a variety of loads (vertical DL & LL, in-plane W, out-of-plane W). However, once analysis is run, the axial diagrams and report shows axial load = 0. It does account for the applied…
In RAM Elements is there a way to input a torsional load on a member? Or does the torsional load have to come from another member (such as a cantilever) with a load on it?
Dear Colleagues,
Say if I have to apply wind on all the four sides (+x / +z / -x / -z) of an irregular structure/geometry, is it okay to consider only 2 positive cases (+x / +z) as Basic Load Case and generate 4 load combinations with 2 positive and…
Applies To
Product(s):
STAAD.Pro
Version(s):
ALL
Environment:
ALL
Area:
Modeling Solutions
Subarea:
Loading
Original Author:
Sye Chakraborty, Bentley Technical Support…
I am using Member loading ( UDL ) and getting warning in the analysis output, which for me seems like a software bug, can you please guide me.
Input
LOAD 20 WIND: WIND X
MEMBER LOAD
13 UNI Y 3.28 0 3.25 0
I have give f1,f2,f3 and f4 as the manual…
I am designing gusset plate connections from a model I brought in from RAM SS. The frame from the model has bracing with and angle of ~75 degrees. As I understand, RAM Connect will not allow me to design the connection with bracing above 70 degrees. Is…
Dear Colleagues,
I happened to open an STAAD file modeled using the previous version, but when opened in my CONNECT Edition 21.03.00.146, i noticed that ONE way loading diagram assigned to a set of beam's FLOOR group, diagram doesn't seem to match as…