• RAM connection Standalone 2023: HSS wall slenderness check in single plate connections.

    Anurag E
    Anurag E
    Hi, I am writing to report an issue with the RAM Connection Standalone 2023 software. I noticed that when I was designing a W beam to HSS column single plate (shear tab connection), the software did not check the slenderness of the HSS wall as per AISC…
    • Answered
    • 2 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Column Splice Connections

    Sabrina Tedeschi
    Sabrina Tedeschi
    Column Splice Joints In RAM Connection, Column Splice (CS) Joints can be created with the following configurations: Shear Connections for Column Splice Joints Connector Design Code Column Sections Connection Options …
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Beam - Girder Connections

    Sabrina Tedeschi
    Sabrina Tedeschi
    Beam - Girder Joints In RAM Connection, Beam - Girder (BG) Joints can be created with the following configurations: Shear Connections for Beam - Girder Joints Connector Design Code Girder Section Beam Section Joint/Connection…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Beam - Column Web Connections

    Sabrina Tedeschi
    Sabrina Tedeschi
    Beam - Column Web Joints In RAM Connection, Beam - Column Web (BCW) Joints can be created with the following configurations: Shear Connections for Beam-Column Web Joints Connector Design Code Column Section Beam Section Joint…
    • 23 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Beam - Column Flange Connections

    Sabrina Tedeschi
    Sabrina Tedeschi
    Beam - Column Flange Joints In RAM Connection, Beam - Column Flange (BCF) Joints can be created with the following configurations: Shear Connections for Beam-Column Flange Joints Connector Design Code Column Section Beam…
    • 17 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Plate bucking checks for BCW single plate shear connections

    Ashutosh Sonpal
    Ashutosh Sonpal
    It appears that RAM Connection (v13 update 4) does not check the plate buckling limit state (analogous to the coped beam web buckling check) for extended shear tab beam to column web shear connections per the provisions of chapter 9 of the AISC steel…
    • Answered
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Ram Connection single plate thickness check

    RFreund
    RFreund
    The maximum shear plate thickness is checked via AISC 360-10 chapter 10 under the "Extended Configuration" checks (page 10-104) to ensure that the moment strength of the plate does not exceed that of the bolt group (to help ensure ductility). There…
    • Answered
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Connection in Staad - Bolt shear ratio in beam-girder single plate connections

    Agustin Rowell
    Agustin Rowell
    Hi Everyone! I am trying to verify a beam-girder single plate connection: I don´t understand why RAM Connection considers this: I understand that it calculates the bolt group capacity as the product of one boly shear capacity by the coeficient…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Extended Shear Tab Buckling Limit State

    Quinton Sweitzer
    Quinton Sweitzer
    I am reviewing (column beam brace) vertical brace connections that use unstiffened single plate connections for the gusset to column web interface. The fabricator has extended the plates out past the column flanges for constructability. After reviewing…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RE: weld size for fin plate shear connection

    Seth Guthrie
    Seth Guthrie
    Most codes have standard tables for verifying the capacity of welded single plates, but in order to use the tabulated values, the welds need to be in a certain range relative to the plate thickness. This insures that the weld is not the weakest link in…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RE: RAM Connection Standalone - Column-Beam-Brace Connection - Assign Single Plate connections from the Design\Assign tab

    Karl G
    Karl G
    Regretfully, this is a program defect that was introduced in version 11.0. The problem and a recommended work around are discussed on the web page below: http://communities.bentley.com/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki…
    • over 7 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Can't Assign CCB_SP to some CBB Joints

    Seth Guthrie
    Seth Guthrie
    Applies To Product: Ram Connection First Affected Version: 11.00.00.164 Found in Version: 11.00.00.177 Fixed in Version: 11.00.01.208 Environment: All Area: General Issue…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RE: Bent Plates in RAM Connection

    Seth Guthrie
    Seth Guthrie
    In my test with 10.00.00.138 I do see a C factor being applied in checks such as the bolt shear check (beam side) for a bent plate designed to AISC 360-10, and in fact my bent plate fails when my shear plate passes. I don't think that build is any…
    • over 8 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum