• Seismic Forces are not getting evaluated correctly ?

    Chetan Mane
    Chetan Mane
    I am working on a platform structure, Which is located on the vessel the height from base is approximately 2.5m I have assigned the seismic forces using the seismic definition option from staad but the forces are not getting assigned correctly, If I visualize…
    • 6 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Application for Structural Supports for Cantilever Overhead Sign Structures (COSS)

    DCS3D Engineering
    DCS3D Engineering
    We are wondering what method / programs you use to analyze and design structural supports for Cantilever Overhead Sign Structures (COSS). Do you use STAAD.Pro to generate COSS models? What engineering codes are used in your country? See videos below for…
    • 2 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • How to model stepped column in RAM SS?

    Oliver Thiessen
    Oliver Thiessen
    I am trying to model a single larger precast column that basically gets split in order to support a steel truss on one side and a precast column with a moment frame on the other. How would you recommend we model this condition? My best idea would be…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • load assigning problem in the staad .

    shanu kumar vishwakarma
    shanu kumar vishwakarma
    I am working on a G+2 public steel building, after modeling I am unable to assign the load on LL.acn anybody rectifies this problem? all the loads assigned are done by old v8i staad pro , but in connect edition this load is not working properly. in the…
    • 11 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Inquiry about Shed Structure Model Analysis

    Mohammmad Al-Amin
    Mohammmad Al-Amin
    Hi everyone , Could anyone please describe me that what is the meaning of the triangle shaped red line in model and what is the purpose of this function?
    • Answered
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Frame Diaphragm Stiffness Clarification

    Zachary Otten
    Zachary Otten
    I am working on a structure that has a flooring system of 3/4" concrete board spanning between cold-form metal joists at 16" O.C. The joists span up to 20' between wide-flange moment and braced frames. In an effort to simplify the modeling for this multi…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • In STAAD Connect Structural Analysis Tapered Member Reference or Size

    Arun Babu K A
    Arun Babu K A
    Dear Team Bentley, I have a curious question to ask regarding Member Size in Properties for Tapered Sections. My queries as below: 1. Why STAAD show Tapered Section with 1,2,3 etc. instead of Member Sizes like (d1-d2)xtw+2*(b1-b2)xtf1/tf2 like this…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Increase thickness of bottom flange of UB section

    Jorge Ochoa
    Jorge Ochoa
    Is it possible to increase the bottom flange thickness on STAAD. this is a measure for and adequacy check
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • The analysis of a stepped column is possible or not?

    soumyaranjan samartha
    soumyaranjan samartha
    PDF Dear communities, Please provide me the solution or method to design & analysis the STEPPED column. For the reference, I have attached the pdf file, please check it & provide me the solution. Thank you.
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Support to simulate uplift force from buoyancy

    Arnie Norhalim
    Arnie Norhalim
    If I were to model a steel pontoon, which supports should I assign to represent the uplift force from the buoyancy in respect to seawater? Thank you.
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Lx and Lz parameter

    abhilashdoss sudhakar
    abhilashdoss sudhakar
    MEM length - 6 m Stiff plate in yellow color at 1.5m interval So shld i give Lz -1.5m or Ly-1.5 Kindly explain me briefly Thank you
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Steel Structures Optimization of Members is not increasing member sizes to make them pass, using Indian code IS 800-2007 LSD

    Arun Chugh
    Arun Chugh
    Steel_Design_Optimizing_M_Intermediate_1_AISC_360-16.STD Steel_Design_Optimizing_M_Intermediate_1._IS800-2007 LSD.STD Why I am getting "Fail" results after using optimization process of commands?; even selecting Ratio 0.9 initially, e.g look into…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • OpenSTAAD : Seismic Definition & Wind Defination

    Umesh Shinde
    Umesh Shinde
    Hell All, I want to know can i provide Seismic Definition & Wind Definition through OpenSTAAD? I want to avoid errors done by my team members while providing definition during loading on structural steel, hence want to make VB based Macro in Staad…
    • Answered
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • How does RAM element perform temperature analysis on a steel building?

    viswak Duddupudi
    viswak Duddupudi
    How does RAM element perform temperature analysis on a steel building? I have a steel building and i need to analyse to analyse the building for a change of 32deg F. My lateral system for the building is BRB's, so I need to check if my temperature deflections…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Problem modelling plates on top of beams for elevated steel water tank

    SUJAY H M
    SUJAY H M
    I am trying to model a Elevated steel water tank with bracing for analysis in STAAD.Pro. While modelling the structure I've encountered a problem and would like your help. The problem is: While the beam offset works perfectly for modelling a beam…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Industrial shed design...side walls opening for wind flow

    hassnain iqbal
    hassnain iqbal
    I am designing an industrial shed. Can I enclose the shed all from the four sides up to the lowest purlin. I have analyzed this shed on staad.pro and its OK as per ASD design methodology under wind loads. I have heard that it is important to give gap…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Brace for multistory building

    Rez Lotfi
    Rez Lotfi
    How can I create a brace for two stories? I have a model which has a half story. I want my braces goes all the way to the beam at the top and doesn't stop at mid story. Is there a way to do this in RAM structural?
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • manually design the plinth beam

    Shivam Sood
    Shivam Sood
    I want to manually design the plinth beam for a steel structure and extract the loads from staad which loads shall i consider? i have 3 critical cases and pinned footings so i have Fx Fy Fz ,how to take them as a load for manually designing the…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Featured LEARN Course: Designing Steel Members

    Gina Mazzulla
    Gina Mazzulla
    With Bentley’s “ Designing Steel Members ” course, learn how to design steel structures in STAAD.Pro utilizing the AISC 360 Direct Analysis Method. Take advantage of STAAD.Pro’s ability to check the deflection of steel members during the design process…
    • over 8 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Blog
  • View related content from anywhere
  • More
  • Cancel