At the vertical brace connection framing-to-beam-column junction , it appears that the Hb force component (required shear force on the gusset-to-beam connection) is considered as the axial force at the beam-to-column connection interface, rather than…
Applies To
Product(s):
RAM Connection
Version(s):
All
Area:
Modeling; Design
What design method is used for force transfer of gusset connections?
RAM Connection uses the Uniform Force Method. Other methods…