• Performing an Analysis in STAAD.Pro

    Sabrina Tedeschi
    Sabrina Tedeschi
    Specifying Load Combinations and Analysis Commands in STAAD.Pro - On Demand Training Learn how to specify load combinations and analysis commands in the STAAD.Pro Analytical Modeler or the STAAD.Pro Physical Modeler. Reviewing the Analysis Results…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • STAAD - Change material after analysis for service check

    Saul Cuen
    Saul Cuen
    According to application notes by AISC, for Direct Analysis Method the UNREDUCED STIFFNESS shall be used for service checks. Now, due to limitations by Staad for DAM (for instance, not TENSION MEMBER available), I proceed to: 1. Reduce module of elasticity…
    • 4 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • WARNING: FYLD parameter has been deprecated for Direct Analysis

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): 22.07.00.160 and Up Environment: ALL Area: Analysis Solutions Subarea: Direct Analysis Original Author: Sye Chakraborty…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Design of Solid slab (Conventional slabs)

    Sulaiman Ade
    Sulaiman Ade
    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RCDC Detailing Failure

    Kunal Jeena
    Kunal Jeena
    How to rectify this failure known as 'Detailing failure' in RCDC
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • SIG Tech Talk: Stability Analysis and Design of Steel Structures using STAAD.Pro CONNECT Edition

    Surojit Ghosh
    Surojit Ghosh
    Tech Talk: Stability Analysis and Design of Steel Structures Presenter: Biswatosh Purkayastha, Senior Structural Engineer, Bentley Systems Surojit Ghosh, Senior Structural Engineer, Bentley Systems Date/Time: Part 1 - 20th May, 11:30 AM GST Part 2 - 3rd…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Announcements Forum
  • DIRECT ANALYSIS AND ITS IMPLENTATION IN STAAD.PRO

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro CONNECT Edition Version(s): All Environment: N/A Area: Analysis Solutions Subarea: Direct Analysis Original Author: Biswatosh Purkayastha…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • How to Modify Notional Load Factor Applied to Auto Generated Load Combinations in STAAD.Pro Connect Edition?

    Alexander Herbin
    Alexander Herbin
    The default notional load factor applied to gravity loads when using the automatic load combination generator is 0.002. Is it possible to automatically generate load combinations in the most recent version of STAAD with a notional load factor other than…
    • Answered
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • "Bentley.Staad not responding" when using notional loads for Direct Analysis

    Stephen Jacob
    Stephen Jacob
    I am using STAAD Connect version 21.00.02.43. I have been trying to create a staad file for direct analysis with notional loads.However, when opening the file as indicated in the image, the software stops responding. This does not happen when removing…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • What is the difference between ITERDIRECT and PDITER options for PERFORM DIRECT ANALYSIS command?

    Stephen Jacob
    Stephen Jacob
    My understanding is that with the PDITER command with every PDelta Iteration the Taub values for Direct analysis is computed and the iteration stops when Taub converges. In which case I cannot understand the purpose of the ITERDIRECT command. Could…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • SIG Virtual Workshop: STAAD for EMEA - Introduction to P-Delta and Direct Analysis

    Patsy Gant
    Patsy Gant
    STAAD special Interest Group for EMEA: Introduction to P-Delta and Direct Analysis Host: Badreddine Ziane, Technical Manager, Bentley Systems, Inc. 24 October 2019 at 11:00 A.M. CEST Register Now P-Delta and Direct Analysis…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Announcements Forum
  • Seismic load by applying notional load

    SANGHUMCHO 조상흠
    SANGHUMCHO 조상흠
    Hello, I am trying to use notional loads(ASCE7-05 Section 11.7.2) as seismic load that's why the building is assigned to Seismic Design Category A. And I will use direct analysis method when designing the building as well. I wonder there is no…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Iterations in DIRECT ANALYSIS

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Solutions Subarea: Direct Analysis Original Author: Sye Chakraborty, Bentley Technical…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Example on Direct analysis with steel design as per AISC 360-10 using STAAD.Pro

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Solutions Subarea: Direct Analysis Original Author: Sye Chakraborty, Bentley Technical…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RE: Notion load factor for 0.002 or 0.003

    Sye
    Sye
    Regarding 1, in Direct Analysis the Taub values are determined iteratively based on the axial force in the member. When you set the notional load factor to 0.003 these iterations are not carried out and Taub is considered as 1 which is what the code recommends…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RE: Blast analysis using Direct analysis method

    Sye
    Sye
    It would not be appropriate to do a direct analysis with a time history loading. Instead what you can do is a Direct analysis for all other cases and then analyze the time history loading using a PDELTA KG. That accounts for the pdelta effects in the…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • DIRECT ANALYSIS with INACTIVE members

    Sye
    Sye
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Subarea: Direct Analysis Original Author: Sye Chakraborty, Bentley Technical Support…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RE: Divergent in load cases

    Sye
    Sye
    The MX releases for the members 81 and 475 were taken out as shown next *81 START MX MY MZ *475 END MX MY MZ 81 START MY MZ 475 END MY MZ The following code commands were redundant and were commented out *PARAMETER 2 *CODE AISC A modified…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • DIRECT ANALYSIS and MEMBER TENSION

    Sye
    Sye
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Subarea: Direct Analysis Original Author: Sye Chakraborty, Bentley Technical Support…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • MEMBER TENSION/COMPRESSION with DIRECT ANALYSIS

    Sye
    Sye
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Subarea: Original Author: Sye Chakraborty, Bentley Technical Support Group …
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RE: Tension members in Staad

    Sye
    Sye
    Gilbert : As of now, STAAD.Pro does not allow Tension/Compression members to be used in a DIRECT ANALYSIS. If TENSION/COMPRESSION is assigned, these attributes are turned off and the members are simply treated as TRUSS members which can take both tension…
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Analyzing & designing a structure made of steel and concrete

    Sye
    Sye
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Analysis Subarea: Original Author: Sye Chakraborty, Bentley Technical Support Group …
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RE: Steel & Concrete Load Combinations & Analysis

    Sye
    Sye
    Using the two analysis types as part of the same analysis model should be fine. I verified it with the attached example. Direct_Analysis_Steel_and_Concrete_Model.std
    • over 6 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RE: STAAD Direct Analysis Method FLEX and AXIAL Parameters

    Sye
    Sye
    While taking a look at the model, I noted a few points Point 1 The error was stemming from the fact that MY MZ releases were applied to these members in addition to the TRUSS specification. So you need to change the MEMBER RELEASE as shown next …
    • over 7 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • STAAD.Pro Analysis Solutions

    Modestas
    Modestas
    Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: STAAD.Pro Support Solutions Subarea: N/A Original Author: Bentley Technical Support Group …
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • View related content from anywhere
  • More
  • Cancel
>