• Stress Comparison of Version V11.03.00.08 and Version V12.08.00.063

    KR Kannan
    KR Kannan
    We have modelled a 20” Pipe with fixed supports at both ends with a point load of 10kN at center, we have analyzed using DNV and found that there is some mismatch in Stress values between version V11.03.00.08 and Version V12.08.00.063. All the relevant…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Forum
  • Critical and High issues released in AutoPIPE CONNECT v.12.08

    Mike Dattilio
    Mike Dattilio
    Items fixed in this version of the application 12.08.01 891921 Modifying Pressure/Temperature data of one point, modifies Pressure/Temperature data of other point(s) Workaround: Perform round trip on the model. …
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • What Critical and High issues were first introduced in AutoPIPE CONNECT v.12.08 ?

    Mike Dattilio
    Mike Dattilio
    891921 Modifying Pressure/Temperature data of one point, modifies Pressure/Temperature data of other point(s) See Also Critical and High issues Bentley AutoPIPE
    • over 1 year ago