• allowable displacement of towers under live load

    Dang Nguyen Khoa
    Dang Nguyen Khoa
    Hi all. In the design of a cable-stayed bridge, what is the allowable displacement of the A and H shaped towers under live load? Best regards.
    • 1 month ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Steel composite bridge

    Dang Nguyen Khoa
    Dang Nguyen Khoa
    Hi all. I hava some question about steel composite brige as follows: 1. To calculator stress point of section, Rm Bridge automatic use short-term section for live load and load case type Non-permanent and use long-term section for load case type Permanent…
    • 2 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • upward deflection of the continuous bridge structure

    Dang Nguyen Khoa
    Dang Nguyen Khoa
    Hi all. In continuous beam structures, the allowable downward deflection of the bridge under HL93 load is L/800. So may I ask what is the upward deflection of the continuous bridge structure under HL93 load? best regards.
    • 2 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Reinf crack for prestressed concrete

    Dang Nguyen Khoa
    Dang Nguyen Khoa
    Hi all. I have a question about Reinf crack for prestressed concrete as follows: If you calculator stress bot of section beam in MinMz_Service exceeding allowable stress tension limit is 0,5 x sqrt(f'c), you can calculator reinf area to control crack…
    • over 2 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Can LARS Bridge load rate ACROW Truss?

    Sujan Shrestha
    Sujan Shrestha
    Can LARS Bridge load rate ACROW Truss?
    • Answered
    • over 4 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Walls in RC Pier

    natkins@mwaeng
    natkins@mwaeng
    I am designing a two stage pier wall. There is no option for just a wall in RC pier. Is there a way to trick the program, I have tried a couple of different options but none have worked. The top wall is tapered in both directions and the bottom wall does…
    • over 12 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • View related content from anywhere
  • More
  • Cancel