• LEAP Bridge Concrete - CONSPAN, CONBOX, RC-PIER, CONSPLICE, and GEOMATH inside OpenBridge Designer CONNECT Edition

    MarcosBeier
    MarcosBeier
    LEAP Bridge Concrete is a consolidated version of LEAP Bridge Enterprise , plus all LEAP standalone products including CONSPAN, CONBOX, RC-PIER , and GEOMATH. In addition, CONSPLICE is also included as an add-on tool. The following new features have also…
    • 2 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Design of Post-Tensioned X-Beam/Box Beam

    Joe
    Joe
    Some state DOTs require x/box beams without CIP concrete deck to be post-tensioned, as illustrated by the image below. The post-tensioned check box in LEAP Bridge Concrete becomes inactive when X-Beam/Box Beam is selected as the beam type. How do I get…
    • Answered
    • over 3 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • "Load Name Must Be Unique" Error

    Dong Wang
    Dong Wang
    Hi, Dear All, After click on "Run Analysis", the error pop-up dialogue tells "loading name must be unique". Did you come across this problem, and how do we fix it? I couldn't figure out what is causing this... Please help. Thanks, Dong
    • over 5 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Bridge Concrete CONBOX Live Load Distribution Factor Manual Input

    Dong Wang
    Dong Wang
    Hi, Dear All, I have a quick question on CONBOX live load distribution factor manual input. The bridge model has a tapered deck. So I am trying to enter in the linearly varying live load distribution factor. I wonder if I have to enter the LLDF at 10th…
    • Answered
    • over 5 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Bridge Concrete CONBOX "Type Of Duct" Update Bug?

    Dong Wang
    Dong Wang
    Hi, Dear All, I found a bug when I tried to update "Type of Duct" in the CONBOX model as in the attached picture. I am able to update "Type Of Duct" and the "Friction Coeff" will be updated accordingly. However, after the model is updated and saved…
    • Answered
    • over 5 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Sudden drop in Vc when providing flared sections in Conbox

    Sandhya Ravindran
    Sandhya Ravindran
    The bridge I'm analyzing has a flared girder and superstructure at the expansion piers. This is the cross section I have defined for this bridge: In order to directly obtain the area of steel required to resist direct shear; I removed the stirrups…
    • over 6 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Conbox/Bridge Connect Concrete : Shear Calculation

    Sandhya Ravindran
    Sandhya Ravindran
    LEAP Conbox/Bridge Connect Concrete : How is the area of steel (Av/S reqd)required to resist vertical shear (Vs) calculated in the Detailed Shear Report when no stirrups are provided in a PT Box Girder design?
    • over 6 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Upgrade to LEAP Bridge Concrete!

    Shri
    Shri
    LEAP Bridge Concrete now includes all of the individual LEAP modules that were previously sold separately (CONSPAN, CONBOX, CONSPLICE, RC-PIER, and GEOMATH.) With LEAP Bridge Concrete you can create 3D bridge models, perform analysis, design, and load…
    • over 7 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Blog
  • View related content from anywhere
  • More
  • Cancel