• How do I copy a pier to multiple locations in LEAP Concrete?

    Devon Kinsman
    Devon Kinsman
    I have a multi-span structure with 3 very similar piers with variable pier caps. In the ABC bridge wizard I defined a generic rectangular cap pier since it did not have the variable depth option in the wizard. I have now redefined one of the piers with…
    • 2 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • How to change the stress limits for the intermediate bent cap from normal exposure (=0.19 sqrt(fc) <0.6ksi ) to severe exposure (=0.0948 sqrt (fc)<0.3ksi) in leap bridge concrete

    Girish Sejekan
    Girish Sejekan
    I need to change the stress limits for the bent cap from normal exposure (=0.19 sqrt(fc) <0.6ksi ) to severe exposure (=0.0948 sqrt (fc)<0.3ksi)
    • 3 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • RCPier P-Delta Analysis increases axial forces in the column.

    Aisulu Saliyeva
    Aisulu Saliyeva
    When running analysis with and without P-delta I noticed there is a substantial increase in the axial column force when P-delta is applied. At the node 1 the difference is about 300 kips. What could be a reason for such an increase? Any insight is appreciated…
    • 8 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Shrinkage Strain Load & Moment capacity error - LBC Substructure

    William Shekarchi
    William Shekarchi
    I have bent that is being constructed in two phases so some shrinkage will happen on the first phase before the next phase is constructed. In the final condition, I could assume the entire shrinkage strain is applied to both sections but that will be…
    • Answered
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Bridge - RCPier Centrifugal Forces Considerations

    Aisulu Saliyeva
    Aisulu Saliyeva
    Hi, There are cases where centrifugal forces produce a moment that actually counteracts the critical moment in the column, does RCPier consider effects due to vehicle cases without centrifugal forces as provisioned in AASHTO Spec (See below excerpt…
    • over 2 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP RC-PIER P-delta effect in load combinations

    Aisulu Saliyeva
    Aisulu Saliyeva
    When checking Show P-delta Effects in the Analysis tab, are the values shown represent values with p-delta effect? For example, are the column/shaft moments magnified with p-delta factor in these load combinations (with a "C" on the end of the LC#)? If…
    • over 3 years ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • View related content from anywhere
  • More
  • Cancel