• Does RC Pier check shear friction in the pier cap (AASHTO 5.7.4)?

    Greg Jackman
    Greg Jackman
    Does RC Pier check shear friction in the pier cap (AASHTO 5.7.4)? I've looked in the output reports and didn't see reference to this spec section. I've also looked in the application help interface and couldn't find it. Note: my application version…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • How to access RCPIER in LEAP

    Dilip Matange [Bentley]
    Dilip Matange [Bentley]
    To access RC-PIER in LEAP users just need to select the Substructure Tab in the Project and hit the Substructure button, as indicated by the red arrows in the screenshot below.