• Quickly Assess Pump Net Positive Suction Head (NPSH)

    Craig Calvin
    Craig Calvin
    Do you want to prevent pump cavitation damage? In this short demonstration, see how the CONNECT Edition of WaterCAD and WaterGEMS enables you to quickly assess pump Net Positive Suction Head (NPSH). Applicable Products: WaterCAD and WaterGEMS CONNECT…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Blog
  • What's New with WaterGEMS and WaterCAD CONNECT Edition Update 1

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): 10.01.00.72 Area: General Overview The CONNECT Edition release of WaterGEMS and WaterCAD introduces numerous improvements and features to help you be more successful. Let…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • CONNECT Edition Update 1 release of WaterGEMS, WaterCAD and HAMMER

    Jesse Dringoli
    Jesse Dringoli
    We are pleased to announce the availability of CONNECT Edition Update 1 of WaterGEMS, WaterCAD and HAMMER: WaterGEMS CONNECT Edition Update 1 (10.01.00.72) WaterCAD CONNECT Edition Update 1 (10.01.00.72) HAMMER CONNECT Edition Update 1 (10.01.00.72…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Blog
  • Calculating Net Positive Suction Head (NPSH)

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem Is there a way of calculate the net positive suction head (NPSH) directly in WaterGEMS and WaterCAD? Solution Starting…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Re: WaterCAD invalid downstream link

    Mohamad Azzam
    Mohamad Azzam
    Dear Bentley, As you know The "suction element" field is no longer used in SewerGEMS V8i SELECTseries 2 (08.11.02.46, released in July), but still in Sewercad, so what if in future if Bentley would to improve pump’s properties and would to add fields…
    • over 13 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: Negative Pressures - WaterCAD

    Mal Sharkey
    Mal Sharkey
    Mikalea, If your reservoir water level is lower than your pumps in a real system, keep an eye on the net positive suction head available (NPSHA) versus net positive suction head required (NPSHR) for your pumps. As you may know you need to make…
    • over 14 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: too much discharge in SewerCAD

    Kim Davis
    Kim Davis
    Negative Pressure warnings at pumps are new as of V8i. The negative pressures occurred all along, and would be apparent if pressures on the upstream side of the pump were viewed, but the User Notification regarding this condition is new. Negative…
    • over 13 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Re: WaterCAD invalid downstream link

    Jesse Dringoli
    Jesse Dringoli
    Hello Mohamad, With the SELECTseries 2 release of SewerGEMS and SewerCAD V8i, the pump orientation behavior actually matches. Both SewerGEMS and SewerCAD only need the "downstream link" attribute for a pump. Regarding NPSH - one of the great things…
    • over 13 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • View related content from anywhere
  • More
  • Cancel