• Hevacomp to openbuilding designer. Heating, gas, Hot and cold pipework design.

    Paul Jacob
    Paul Jacob
    As i understand. Bentley Hevacomp is being retired and replaced with openbuilding designer. I cannot find any training for openbuilding designer to do with plumbing systems. Only ductwork ventilation systems. I would like to know how to design a heating…
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Copying CWS Outlets to HWS

    Gerald Robinson
    Gerald Robinson
    Is it possible to copy outlets between CWS and HWS in Netsys? This would save a lot of time. Thanks
    • over 5 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Same Loading Units Different Flowrates

    Shane Regan
    Shane Regan
    For other users who may experience the above - this issue was due to different pipe sizing standards at each outlet. Please find further details here.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Inconsistent Flow Rate at Outlets

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Netsys Subarea: HWS and CWS Problem Description Outlets in HWS or CWS systems may have differing Loading Units, despite the outlets…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: How to include Hot water cylinder in Netsys (CWS)

    Shane Regan
    Shane Regan
    Hi Jozef, The guidance here should assist with modelling this.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Same Loading Units Different Flowrates

    Jamie Sanderson
    Jamie Sanderson
    Hi I have created a HWS system consisting largely of en-suits of bedrooms. Each en-suite has a two number of basins and 1 shower nozzle. They are calculated using the same method (BS EN 6700), and have the same loading units. They branch coming in…
    • Answered
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • HWS resistance projects

    Duncan Brown
    Duncan Brown
    Test projects demonstrating: twin pipe outlet connections will include extra outlet resistance when sizing circulation pumps. single pipe outlet connections will not include extra outlet resistance when sizing circulation pumps. These files…
    • HWS Test Projects - Circulation resistance.zip
    • over 6 years ago
    • Hevacomp
    • Hevacomp Files
  • CHP will not connect to an HWS sysytem

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview CHP cannot be directly and solely connected to HWS. Method At this time,…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: de-active snap grid

    Shane Regan
    Shane Regan
    Hi Arun, you can change this setting by going to Pipes > Defaults, and deselecting the Snap Grid option. Also, if you wish to change the Ortho settings you can do so by going to Defaults>Ortho. You can see this operation if you view this document .
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Including Hot Water System feed in your Cold Water System

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipework Design Overview Often as part of a Cold Water System (CWS) there will be a supply to…
    • 5 months ago
    • Hevacomp
    • Hevacomp Wiki
  • Netsys HWS Sample Project

    Duncan Brown
    Duncan Brown
    Netsys HWS Sample Project - unzip into new folder and open with the Netsys HWS program
    • SAMPLEHWS.zip
    • over 7 years ago
    • Hevacomp
    • Hevacomp Files
  • Energy Calculation - HWS demand

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Daily HWS demand for the Energy Calculation is based on litres/per person…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • View related content from anywhere
  • More
  • Cancel