• Calculations - Occupancy and heat gains

    Drew Roche
    Drew Roche
    What takes precedence for people gains - is it the Standard room input data, or the definition of activity types? VS. The activity types are referenced below are from this thread: https://communities.bentley.com/products/building/performance/w/building_performance__wiki…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain Queries

    Graeme Matheson
    Graeme Matheson
    I have turned off infiltration, ventilation, occupants and casual gains from my model to test the solar load portion only. However I still see loads attributed with "Convective" and "Latent" (albeit small). Should these loads exist in my calculation…
    • Answered
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain calculation - Importance of accurate input data

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Results Overview Unusual results are likely to occur if Building model data is inadequate. Method Comprehensive…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CIBSE Gain - Temperature rise

    Michael Charleson
    Michael Charleson
    I understand that you get different heat gains in the following scenarios: Within CIBSE gain tool allow temperature to rise by 1degC Within room data increase summer design temp by 1degC There is a calculation procedure for the first scenario…
    • Answered
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain Calculation - Why does the graph show double the table results?

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When producing results in the CIBSE Gains program, the graph is showing double…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Discrepancies between result table and graph

    Duncan Brown
    Duncan Brown
    Hi Gary - With regards your query, this document should provide you with an answer. Best regards,
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Very high CIBSE Solar Gains

    Gary Jackson
    Gary Jackson
    I modelled a simple 5mx5m glass box with no heat transfer across the floor or ceiling and I created a custom glass to replicate a Pilkington glass (U-Value of 0.6 and g-factor of 0.55). When I checked the solar gains using CIBSE Gains they were 10.8kW…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: CIBSE Gain - Results Breakdown

    Stephen Brown
    Stephen Brown
    Matthew, you have probably turned on Temperature Rise in the Design Data tab. When you use Temperature Rise the individual loads are combined in the underlying equations and cannot be accurately split out afterwards.
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum